Failure Removal
Please check the following issues before sending to designated repair offices.
Symptoms
Possible Causes
Battery has no power
M o t o r i s n o t
Metal tube, electric floor had,
working
battery pack is not assembled
correctly to the mainbody
Dust cup is full
Filter is blocked by dust
Low suction
Floor head hose or brushroll
blocked
Battery not fully charged
Short run time
after charging
Battery old aging
Note: If any other failures occurred, which need professional tools, in order to avoid danger, the machine
must be repaired or replaced by manufacturer, other maintenance offices or professionals from similar offices.
Product Specification
Technical Parameter
Model No
Rated Voltage
Rated Power
Adaptor Input Voltage
Adaptor Output Voltage
Model No of Electric Floor Head
Rated Power of Electric Floor Head
Battery pack capacity
Charging time
Solutions
Charge the vacuum cleaner
Check the accessories are assembled
correctly to the mainbody
Empty dust cup
Clean or replace HEPA
Clean the floorhead
Follow instruction manual to fully charge
the battery
Replace new battery
JV83
25.2V
450W
100-240V ~ 50/60Hz 0.8A
30V
600mA
T-EB110A
30W
2500mAh
5h
11