FAN ONLY
If you want to make air circulate without any temperature control,
follow these steps:
1. Set the MODE selector switch to "FAN"
2. Press the ON/OFF button and switch the air conditioner ON.
ADJUSTING THE FAN SPEED
AUTOMATIC
Simply set the FAN SPEED selector to the
. A microcomputer automatically controls the fan speed when the
EG
AUTO mode is selected. When the air conditioner starts operating,
the difference between the room temperature and the set
temperature is detected by the microcomputer which then
automatically switches the fan speed to the most suitable level.
NOTE
In FAN Only mode the fan speed is adjusted automatically as in
cooling mode.
WHEN DIFFERENCE BETWEEN
ROOM TEMPERATURE AND SET
TEMPERATURE IS
Cooling and
dehumidifying modes:
Heating mode:
COOL / DRY / HEAT / FAN
NOTE
The above mentioned data make reference to the conditioner
operating when the sensor on the remote control unit is ON. (Refer
to temperature sensor selector). If the sensor on the indoor unit
is being used then actual operation will slightly differ from that
described in the above tables. (
control unit display).
MANUAL
If you want to manually adjust speed just set the FAN SPEED
selector as desired.
High speed
SLEEP MODE
The SLEEP mode enables you to save energy.
1. Set the MODE selector to cool, dry or heat.
2. Press the SLEEP button.
3. The
mark appears on the display. Press the SLEEP
button again to release the SLEEP function.
What does the SLEEP mode mean?
In this mode, the air conditioner will cool or heat the room to the
set temperature, and then the thermostat will make the unit pause.
After about 1 hour, the air conditioner will automatically reset the
set temperature as follows (also refer to graphs).
OPERATING MODE
Heating
Cooling and Dehumidifying
When the room temperature reaches the new set value, the
thermostat will cause the unit to pause. After about 1 hour the
temperature will be raised by 1 °C in cooling, or lowered by 1 °C
in heating. This enables you to save energy without sacrificing
your comfort.
.
FAN SPEED
2 °C and over
Between 2 and 1 °C
Medium
Below 1 °C
2 °C and over
Below 2 °C
Medium
) Sign shown on the remote
Med. speed
Low speed
SET TEMPERATURE CHANGE
Lowered by 1 °C
Raised by 1 °C
COOLING AND DEHUMIDIFYING
Setting temperature
1°C
1 hour
position
SETTING THE TIMER
A) HOW TO SET THE OFF TIME
1. Press the ON/OFF button to start the air
conditioner.
2. Press the TIMER button till the OFF sign
High
blinks.
3. Press the + or - (HOUR) button until the
Low
desired value is displayed.
4. Press the SET button to activate the
High
timer.
B) HOW TO SET THE ON TIME
1. Press the ON/OFF button to stop the air
conditioner.
2. Press the TIMER button till the ON sign blinks.
3. Press the + or - (HOUR) button until the desired value is
displayed.
4. Press the SET button to activate the timer.
C) HOW TO SET A PROGRAM FOR DAILY ON/OFF OPERATION
(OR VICE VERSA)
1. Press the TIMER button till the ON sign blinks.
2. Press the + or - (HOUR) button until the desired value is
displayed.
3. Press the TIMER button again, the OFF sign blinks.
4. Press the + or - (HOUR) button until the desired value is
displayed.
5. Press the TIMER button, then the SET button to activate the
timer.
D) HOW TO CLEAR THE TIMER
Press the CLEAR button if you want that every timer operation will
be cleared.
NOTE
If the procedure to set the timer is not completed, by pushing the
SET button, within 15 seconds the timer operation will be cancelled
and the last set-up is restored.
8
Room temperature
1°C
1 hour
TIME
HEATING
Setting temperature
1 C
1 hour
1 hour.
2
1
Room temperature
1 C
TIME
4
3