■ VOLTAGE CONVERTER
box and allows you to operate a gate opener or electric strike plate at any time.
1 - Remove the batteries
2 - Remove the battery compartment cover
3 - Attach the printed circuit board :
a) tilt the circuit board
b) wedge it between the tab and the springs
c) fasten the board to the box using the two screws supplied
4 - Plug the connector into the printed circuit board
5 - Connect the wires from a transformer or an automatic gate opener by running them
through the knockout. Trim the knockout to the diameter of the cable.
6 - Leave the battery compartment cover off.
tab
Control, such as a push button, to be
connected to the gate opener auxiliary
12 / 24 V AC / DC power supply
(do not reverse the polarity)
Never power the converter with a direct
ADSF 10003 replaces the 4 batteries in the electronic
WE
screws
control
230 V~ supply
Converter
WE
provides the
tions: press it for at least two seconds to
operate an automatic gate opener or
press it briefly to open an electric strike
plate. These functions are enabled both
at any time when the system is on.
PCB connector
knockout
springs
GB
15
ADSF 10003
button with two func-
not used with this version