ProMax – Proportioning System
SUCTION HOSE AND TIP INSTALLATION :
Step 7
Select a suitable tip and insert it
completely into the barbed
tip seat as shown.
To determine the correct tip refer
to the tip chart below.
Step 10
Tip calibration:
1. Fill a graduated cylinder with
the concentrated product.
2. Using the chart in the manual,
select and insert the tip closest to
the desired dilution ratio.
3. Insert the pick up hose into the
graduated cylinder.
4. Put the outlet tube into a open
container and push the button or
lever in order to activate the
system. Draw up the product until
the pick up tube is completely
filled.
5. Switch the system off and
insert the delivery hose in a 1 gallon (or 5 liter) container.
6. Mark the level of the product in the graduated container
7. Switch the system on again until the 1 gallon (or 5 liter) container is
completely full.
8. Switch the system off and read the quantity of product in the
graduated container.
9. The difference in the product levels for points 6 and 8 indicates the
amount of product mixed per gallon (or liter).
ProMax
Step 8
Connect the suction
hoses by sliding completely over
the barbed tip seat as shown
Chemical
Water
Chemical
Water
graduated
+
tank
Chemical tank
tank
Chemical
tank
Cod. 0000137667
Step 9
CERAMIC
WEIGHT
Cut the tubing to the required
length. Connect the yellow foot
valve / filter in to the hose as
shown above. Slide the ceramic
weight over the tube and as far as
possible over the barbed fitting on
the yellow foot valve.
Step 11
Water
Use a cable tie to secure the tube
on the barbed tip seat. For a 4
product selector, repeat the
operations from step 7 to 11 for
each product
rev. 1.5
EN