Water Supply And Drain Connections - Hoshizaki FM-481AGE-HC Manual De Instrucciones

Ocultar thumbs Ver también para FM-481AGE-HC:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
ENGLISH
* This appliance requires a separate 220 - 240VAC,
1 3 A s u p p l y. T h e e l e c t r i c a l s u p p l y m u s t b e
protected by a suitable circuit breaker.
* Usually an electrical permit and services of a
licensed electrician are required.
* If the supply cord and/or the plug should need to
be replaced, it should only be done by a qualified
service engineer.
* In accordance with the requirement of the IEC
standard, the maximum permissible system
impedance (Zmax) at the interface point of the
power supply to be connected with this icemaker
must be 0.2908+j0.18175 ohm. Determine in
consultation with the supply authority, if necessary,
that the icemaker is connected only to a supply of
0.2908+j0.18175 ohm or less.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured Green-and-Yellow must
be connected to the terminal in the plug which is
marked with the letter E or by the symbol
coloured Green or Green-and-Yellow. The wire
which is coloured Blue must be connected to
the terminal which is marked with the letter N or
coloured Black. The wire which is coloured Brown
must be connected to the terminal which is marked
with the letter L or coloured Red.
* Should the socket outlets in the installation site not
be suitable for the plug supplied with your product,
the plug must be removed (cut off if it is moulded
on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used without
a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer 's
reference number stamped on the plug.
S uppl y of repl acement fuse cov ers can be
obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to BS
1362.
3. WATER SUPPLY AND DRAIN
CONNECTIONS
Connect to potable water supply only.
Note: A plumbing permit and services of a licensed
plumber may be required in some areas.
* The connections to the mains water supply must
be made in accordance with the countries' current
requirements of the Water Supply or Water Fittings
Regulations.
* Icemaking water must be potable water. Where
scaling can be caused by water quality, installation
of an external filter or softener is recommended.
Contact your local water treatment professional or
Hoshizaki service agent.
* Water supply pressure should be minimum 0.05
MPa (0.5 bar) and maximum 0.8 MPa (8 bar).
If the pressure exceeds 0.8 MPa (8 bar), use a
proper pressure reducing valve. Do NOT throttle
or
back the supply tap.
* The icemaker drain is gravity flow, so ensure drain
pipe has an adequate pitch or fall.
* Water should drain into an open trap.
* Be sure to use the new hose-sets supplied with the
appliance. Do not reuse any old hose-sets.
II. OPERATING INSTRUCTIONS
1. This icemaker is designed to produce and
store edible ice. To keep the icemaker
hygienic:
* Wash your hands before removing ice. Use
the plastic scoop provided (accessory).
* The storage bin is for ice use only. Do not
store anything else in the bin nor use other
2
WARNING
WARNING
Tabla de contenido
loading

Este manual también es adecuado para:

Fm-481age-hcnFm-300afe-hcFm-300afe-hcn

Tabla de contenido