do not walk on wet area until all power has been
turned off. If shut-off box is in basement, call electric
company or hydro authority to shut-off service to
house, or call your local fire department for
instructions. Remove pump and repair or re place.
Failure to follow this warning can result in fatal
electrical shock.
Do not lift pump by power cord.
Specifications . Installation
Performance
GPH (LPH) at total feet (m) of lift
Series
HP
5
(1.5m)
Capacity Gallons(L)/Hour
FPZS25T
1/4
2700
(10221)
(8176)
FPZS33T
1/3
3060
(11583)
(9085)
FPZS33V
FPZS50T
1/2
3660
(13855)
(11356)
FPZS50V
FPZS75V
3/4
4200
(15899)
(13400)
Specifications
Power supply required...................................115V, 60 HZ.
Liquid Temp. Range..........................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.).............15 Amps
For parts or assistance, call Flotec Customer Service at
10
15
20
(3m)
(4.6m)
(6.1m)
at height
2160
1500
-
(5678)
2400
1680
660
(6359)
(2498)
3000
2160
960
(8176)
(3634)
3540
2820
1800
(10675)
(6814)
Discharge:........................................................ 1-1/2" NPT
NOTICE Do not reduce size of discharge pipe or hose below
1-1/4" diameter. If discharge is too small, pump will
overheat and fail prematurely.
This pump is designed for use in a residential sump only.
Only pump water with this pump.
NOTICE This unit is not designed as a waterfall or fountain
pump, or for applications involving salt water or brine! Use
with waterfalls, fountains, salt water or brine will void
warranty.
Electrical & Switch Specifications
No flow
Series
HP
FPZS25T
1/4
shown
below
FPZS33T
1/3
20 ft
FPZS33V
1/3
(6.1m)
FPZS50T
1/2
22 ft
FPZS50V
1/2
(6.7m)
FPZS75V
3/4
22 ft
(6.7m)
24 ft
(7.3m)
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.
Motor
Switch Setting in inches
Full
Branch
Load
Circuit Req.
On
Amps
(Amps)
3.9
14 (35.6)
4.0
14 (35.6)
4.0
7.5 (19.1)
15
4.1
14 (35.6)
4.1
7.5 (19.1)
5.5
7.5 (19.1)
1-800-365-6832
(cm)
Off
5 (12.7)
5 (12.7)
3 (7.6)
5 (12.7)
3 (7.6)
3 (7.6)