Output
RDX
COM
BAT

14. Jumper setting

Jumper
JR1
Display mode selection.
Jumper
JR5
Selection of power supply - auxil-
iary board.
EN
Value of
accessories
The control panel is fitted with a housing for modules of the 6ZENRS
radio receiver type (433.92 MHz).
Can be replaced with a module of the ZENPRS radio receiver type (868.35
6ZENRS
MHz).
ZENPRS
When using slot-in radio boards, remove the RDX module. The display
will show
WARNING: the modules must be inserted and removed with the power
supply disconnected.
COM - This allows the functioning configurations to be saved using the
function
The saved configurations can be recalled using the function
COM - The storage module allows the remote controls to be stored. If the
BIXM R2
control panel is replaced, the storage module being used can be inserted
in the new control panel.
WARNING: the storage module must be inserted and removed with
the power supply disconnected, and paying attention to the positioning
direction.
BAT - Battery-powered operation.
The batteries are kept charged when the power supply is on. If the power
supply is off, the panel is powered by the batteries until the power is re-
establish or until the battery voltage drops below the safety threshold.
The control panel turns off in the last case. WARNING: the batteries must
SBU
always be connected to the control panel for charging. Periodically check
the efficiency of the batteries.
NB: the operating temperature of the rechargeable batteries is from
+5°C to +40°C.
For advanced control of battery-powered operation, refer to the menu
Description
Description
Description
.
.
OFF
Display mode.
Only the v alues and pa-
rameters present can be
displayed.
1
30
AUX1 powered from 0-1.
(default)
22
ON
Maintenance mode.
Only the v alues and pa-
rameters present can be
displayed and modified.
A c t i v a t e d m a i n t e n a n c e
mode is indicated by the
permanent switching on of
the right-hand point on the
display.
1
30
AUX1 powered from 0-30.
.
.