5A)Press the SET/PROG
key until the RED led of
the 2nd level of PEAK
CURRENT I
A) starts flashing
• Adjust the parameter by
turning the special dial
6A)Press the SET/PROG
key until the RED led of
the 1st level BASIC
CURRENT (5 ÷ 100 A)
starts flashing
• Adjust the parameter by
turning the special dial
7A)Press the SET/PROG
key until the RED led of
the PULSATION FRE-
QUENCY (0.5 ÷ 500
Hz) starts flashing
• Adjust the parameter by
turning the special dial
ATTENTION: go on to point 8)
EASY PULSE METHOD
3B)Press the "pulsation"
button until the EASY
PULSE function is
working
(5 ÷ 200
2p
ATTENTION: with EASY PULSE
working and adjusting the value of the
1st level PEAK CURRENT (I
have the values of the other 1st level
parameters (I
ATTENTION: adjusting the value of the
2nd level PEAK CURRENT (I
EASY PULSE is working, you will have
the values of the other 2nd level para-
meters (I
2b
10) Use the CYCLE function for PUL-
SATING TIG welding
4B)Press the SET/PROG
key until the GREEN
led I
and the RED led
1
I
will start flashing;
p
st
adjust the 1
level
PEAK CURRENT I
1p
÷ 200 A); value by tur-
ning the special dial.
) you will
1p
, f) in synergy
1b
5B)Press the SET/PROG
key until the RED led of
the 2nd level PEAK
CURRENT I
(5 ¸ 200
2p
A) starts flashing
• Adjust the parameter by
turning the special dial
) while
2p
, f) in synergy
8) If you want a test weld,
the led of the selected
parameter will flash
and the value of the
parameter being set
will be visualized on
the display while this is
being done
9) Keep pressing the
SET/PROG key for
more than 1 second to
leave the weld parame-
ter setting phase
19
NOTE: The RED LED I
and the GREEN LED I
remain on continuously
during the welding process
and the current value
being used for welding will
be visualized on the
(5
display
INPUT STORAGE
ATTENTION: The GREEN LED I
be on continuously to enter the input
storage phase
1) Keep pressing the
SET/PROG key (for
about 3 seconds) until
the letters Pr appear
on the display
2) Turn the dial to select
the number of the pro-
gramme where input
must be stored
3) Keep pressing the
SET/PROG key until
the letters Sto appear
on the display
4) Input has been stored
PROGRAMMED WELDING
Once the programme has been memo-
rized the operator can only weld with the
pre-set values and cannot change any
of the parameters. Go to MANUAL
welding to make any changes.
p
1
must
1
Tabla de contenido
loading