Kohler K-302 Guia De Instalacion página 6

Ocultar thumbs Ver también para K-302:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4. Shower Only Installations
NOTE: Shower only installation require 2-valve yokes.
NOTE: Typical dimensions for bath and shower installations are
shown on the rough-in diagram.
NOTE: Refer to the trim installations for specific requirements.
NOTE: Refer to the handle installation instructions for possible
rough-in depth requirements.
Unless otherwise instructed, rough-in the supply yoke 2-1/4" (5.7
cm) minimum to 3" (7.6 cm) maximum from the centerline of the
yoke to the outside of the finished wall.
Install 1/2" hot and cold supply tubing.
If specified, install the screwdriver stop valves.
Using a 3/8" hex wrench, remove the aspirator from the yoke and
discard.
Install a plug in the spout piping opening.
113212-2-AC
72"
(182.9 cm)
24"
To Floor
(61 cm)
Plug
6
Kohler Co.
Tabla de contenido
loading

Este manual también es adecuado para:

K-303K-6934

Tabla de contenido