Temperature Display; Temp -Set; Alarm -Set - Electrolux MRF 120/35 Instrucciones De Manejo

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
11
On the display screen the internal refrigerator temperature is displayed.
For /35 appliances:
If the temperature is colder than -60°C, the display
temperatures warmer than -10°C will be shown with
For /86 appliances:
If the temperature is colder than -99°C, the display
temperatures warmer than -60°C will be shown with
12
By „Temp-Set" we mean the desired internal temperature of the refrige-
rator. This temperature has been preset in the factory. If needed it can be
adjusted. Such adjustment must be done by a technician from the
Service Centre. If the „Temp-Set" is changed, the „Alarm-Sets" change
automatically.
In order to be able to detect the „Temp-Set" set, press the „SET" key. The
„Temp-Set" LED will light up and the „Temp-Set" value set will be dis-
played as long as the „SET" key remains pressed.
Pre-set values:
13
By „Alarm-Set" we mean the maximum and minimum admissible internal temperature. It can be modified as follows, according to
needs :
For /35-models :
Alarm COLD = minimum value set: -55°C , maximum value set: 5° below the „Temp-Set".
Alarm WARM = maximum value set: -15°C, minimum value set: 5° above the „Temp-Set".
For /86-models :
Alarm COLD = minimum value set: -95°C, maximum value set: 5° below the „Temp-Set".
Alarm WARM = maximum value set: -65°C, minimum value set: 5° above the „Temp-Set".
By pressing the relative WARM and COLD keys the „Alarm-Set" values set can be detected. The relative „WARM-alarm" or „COLD-
alarm" LEDs light up while the set temperature is displayed. The following values have been preset:
For /35-models :
For /86-models :
In the setting of the „Alarm-Set" proceed as follows:
Alarm-Cold = Press the "SET" and "COLD" key at the same time; the
"Alarm-Cold" LED lights up and the temperature changes in 1ºC stages
from the set value up to the end value. Once this value has been reached,
the display moves back to the original value. In order to set a value, sim-
ply release the keys once the temperature required is displayed.
Alarm-Warm = Press the "SET" and "WARM" key at the same time; the
"Alarm-Warm" LED lights up and the temperature changes in 1ºC stages
from the set value up to the end value. Once this value has been reached,
the display moves back to the original value. In order to set a value, sim-
ply release the keys once the temperature required is displayed.
T
EMPERATURE
For /35 appliances:
-35°C
For /86 appliances:
-82°C
Alarm COLD : -40°C
Alarm COLD : -87°C
D
ISPLAY
- - - -
will appear;
.
II II
- - - -
will appear;
.
II II
T
-S
EMP
ET
-35.0
A
-S
LARM
ET
Alarm WARM : -30°C
Alarm WARM : -77°C
-50.0
-20.0
- 7 -
/35
/86
II II
-10°C
-60°C
- - - -
TEMP
SET
ALARM
°C
MEMORY
MEM
TEMP
SET
ALARM
°C
MEMORY
MEM
TEMP
SET
ALARM
°C
MEMORY
MEM
-60°C
-99°C
SET
SET
SET
Tabla de contenido
loading

Tabla de contenido