Electrical Connection; Functioning Of The Lock; Electronic Summary; Switching On - Electrolux MRF 120/35 Instrucciones De Manejo

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
7
Before carrying out the electrical connection of the equipment, make sure that the data stated on the data plate (in the top left on
the internal container or on the back side) correspond to the local values. It is important to connect the equipment to a ground
clamp.
Before connecting the equipment and activating it for the first time, it must be in a vertical position for about 30 minutes. If the equip-
ment was transported horizontally, wait 4 hours.
To avoid the equipment not functioning due to any breakdowns to other electrical equipment it is necessary to be connected to a
separate electrical circuit. In no case must it be connected together with other electrical equipment by means of a multiple plug, to
a single electrical outlet.
8
When the key is in the horizontal position the door is closed and the key can be removed.
If the unit is to be left permanently open and accessible to all (daytime operation), turn the key 90° to the right to the vertical posi-
tion and remove it.
Do not store the keys in reach of children or near the refrigerator.
9
(electric failure)
ON
AC FAIL
OFF
AC OK
key switch
green LED
(operation)
10
To operate the equipment turn the key switch on the command panel to the „ON" position. In this position the key can be taken
out to avoid the equipment from disconnecting by mistake.
Upon ignition all the LEDs light up constantly for about 5 seconds. The acoustic alarm is simultaneously activated and the following
temperature value appears on the screen
Following this initialization only the green LED remains lit. It indicates that the equipment is connected and that it is live. The present
temperature inside the refrigerator appears on the screen now and corresponds to room temperature after ignition. As the display
shows temperatures in a particular range only, temperatures below this range are shown with
After the first ignition check the correct functioning of the equipment and if the set temperature is reached after 24 hours.
Upon the first ignition the alarm remains inactive until the internal temperature reaches the set value. Only after this occurs is the
alarm active.
When switching the appliance off with the key switch, all parameters of the electronics are set back to factory settings.
E
LECTRICAL
F
UNCTIONING OF THE LOCK
E
LECTRONIC SUMMARY
red LED
temperature
display
.
-i8.8
C
ONNECTION
desired internal
temperature
Temp
Alarm
°C
Memory
maximum or minimum
admissible internal
temperature
S
O
WITCHING
N
- 6 -
keys
LEDs
S E T
WARM
COLD
COLD
WARM
RES
COLD
MEM S E T
WARM
memory function
keys
- - - -
and above with
.
II II
Tabla de contenido
loading

Tabla de contenido