SERVICE
When a new battery is plugged
in, the following may be displayed
when service is required:
- this icon is displayed
- a service message is displayed
(see below)
- a voice message is heard.
● Go to "Maintenance" menu and press OK
● Go then to "Service" and press OK
When no service is required, "none" is displayed.
There are 3 service levels:
Level Number of
tightenings
1
25,000
2
250,000
3
500,000
** this type of service is required for heavy duty
applications only.
● Refer to the chapter "Instructions" next page.
HOW TO RESET AN ALARM
Once the service is performed, you have to reset
the indicators:
● Go to the "Maintenance" menu and press OK.
● Then go to "Service" and press OK
Press OK to reset the current
Reset
indicator.
Press OK: indicators will not
Reset
be reset.
Service type
calibration
intermediate**
standard
TOOL INFORMATION
● Refer to the "Maintenance" menu (for reading
only).
Total
Number of tightenings since the
counter
manufacturing of the tool.
Battery
The current voltage value is
displayed. The "Low battery"
message is displayed when lower
than 32 V. At 31 V, the tool stops.
Software
FX.YY.ZZ
version
Serial
14A64685 for example.
number
28 / 108