UNBALANCED LOAD
E9
MAX UNBALANCED
E10
LOAD
CLOTHES HOT
E11
UNLOCK ERROR
E12
MODEL ERROR
E13
WEIGHING ERROR
E14
FRONT INFLATION
E15
ERROR
REAR INFLATION ERROR
E16
WEIGHING ERROR
E23
This message appears when the unbalanced load micro switch is activated once
during the spin cycle.
Only the option "end" is given. When this is pressed, the programme will end, and
the door is unlocked. In addition, the text "TRY TO REDISTRIBUTE LOAD"
appears in the error message.
The unbalanced load micro switch is activated once during the spin cycle.
Only the option "end" is given, the programme ends, and the door is unlocked
when this button is pressed.
A programme execution finishes but the water temperature inside the tub exceeds
50 ºC.
The 2 options "continue" or "end" are displayed. If we press continue, the machine
again checks the temperature, unlocking the door only if it has dropped below
50ºC. The same message is displayed again if the temperature has not
decreased. If we press "end", the programme will end and the door unlocks.
The machine detects that the door cannot be unlocked at the end of a programme.
This error occurs after 3 attempts to unlock the door every 20 seconds.
Only the option "end" is given. When this option is pressed, the machine repeats
the 3 attempts to unlock and if it cannot unlock the door the error is given with the
following text: "DO NOT FORCE THE DOOR. CALL THE TECHNICAL SERVICE".
On trying to select the model, the machine does not detect an activated range
input (low, medium, high, sanitary) or more than one range is activated.
The option "back" is given to exit the menu, returning to the screen where the
model code is entered.
This error is detected in the following cases:
o
Both during selection and while running, if the two pressure switches
("Front Pressure Switch" and "Rear Pressure Switch") are open.
o
If, while running, either of the pressure switches is open.
o
If during selection or while in tilt mode, the two inputs of the external
control command "Forward Tilting" and "Backward Tilting" are closed.
o
If while running a programme, communication is lost between the control
and auxiliary cards,
the option "OK" is displayed. If the machine is currently running a programme, this
will be ended.
While the weighing kit is active, when the output "front inflation" is activated and
the input "Front pressure switch" is not opened for 5 minutes.
While the weighing kit is active, when the output "rear inflation" is activated and
the input "Rear pressure switch" is not opened for 5 minutes.
On pressing "Start" to run a programme, if the auxiliary card is connected and
communicating correctly, and it is not possible to communicate with the weighing
appliance, this error is displayed.
The two options "OK" or "Cancel" are displayed. Press "Cancel" to abort the
programme and return to the selection menu. Press "OK" to continue running the
programme with the nominal weight value of the machine.