4 PROGRAMMES

There is a programme library consisting of all the programmes installed by default, together with the
programmes created by the user.
Before explaining the programme management (see section 5.1), details are given of their parameters
and of the standard programmes found in the library.

4.1 Cycle parameters

Each programme is made up of a series of cycles, consisting of a set of parameters which can be
configured, depending on the cycle type in question.
4.1.1

Parameters for soak, prewash, wash or rinse cycles:

Cycle name: Name identifying the cycle. This is not the text displayed on the Run screen,
but the text which identifies a created cycle.
Time: Value, in minutes, of the cycle length. Range can be configured from 1 to 99.
Temperature: Temperature, ºC or ºF, of current cycle.
Range can be configured from 20ºC to 90ºC.
Level: Water level at which cycle should be run.
There are 5 types of level: Minimum (1), Low (2), Medium (3), High (4), Maximum (5)
Please refer to table of levels by model
Speed: Speed of current cycle. There are 4 different speeds to select from: Minimum
(1), Low (2), Normal (3), High (4).
Please
(seconds) / stop time (seconds)). Range can be configured from 1 to 99.
The drum alternately turns to the left and to the right.
Hot water: Load water from the hot water inlet (Yes/No).
Cold water: Load water from the cold water inlet (Yes/No).
Auxiliary: Load water from the auxiliary water inlet (Yes/No).
Water adjustment: Load water from one or other inlet depending on the temperature
(Yes/No).
T1, T2, T3: Load water from any of the tanks if recovery KIT is fitted.
indicating which outlet should be used if the recovery kit is active.
drainage or going to the next cycle. Configurable parameter only if the cycle temperature is
equal to or higher than 40ºC. Range can be configured from 30ºC to cycle setting.
In addition to selecting the cooling value, there is a button to enable or disable this option.
refer to table of speeds by model
Wash rate: Sequence of movement that washing machine must follow (run time
Water inlet: This indicates the selection of the required water inlet.
Drainage: This displays whether the water should be drained at the end of the cycle,
Cooling: Option that permits the temperature in a cycle to be lowered before
(see section 4.4.). Range can be configured.
(see section 4.4.). Range can be configured.