6. Technical specifications

Model
Thrust and traction force (F
Course lengths (S
Input voltage (U
)
N
Current absorption at nominal load (I
Power absorption at nominal load (P
Travel speed without load
Length of run without load
Electrical insulation
Type of service (D
Max. and min. temperatures for function
Degree of protection for electrical devices
Adjustment of socket at casing
Connection in parallel of two or more motors
Connection in tandem or in series
Holding nominal force (it can vary according to
the chosen brackets)
Limit switch stop at opening and closure
Protection against overload at opening and
closure
Feeding cable length
Dimensions
Weight
Information presented in these illustrations is not binding and is also subject to variation without prior notice.
(*) Technical personnel can shorten track runs by adjusting the internal limit switches.

7. Electrical supply

Depending on which model is used, the actuator can function on 24V
in the lead, or on 110-230V~ 50/60 Hz with a three cable lead.
Low tension actuators 24V
tension of 24V
7.1. Section choice of supply cables
Tension falls due to current passage in conductors is a basic aspect for safety and
good appliance function. It is therefore extremely important that the conductor section in
function of cable length is calculated correctly. The following table indicates cable
lengths for an actuator connected at nominal charge.
CABLE SECTION
0.50 mmq
0.75 mmq
1.00 mmq
1.50 mmq
2.50 mmq
4.00 mmq
6.00 mmq
)
N
)
V
)
R
must be powered using a security feeder with an output
(min. 20,4V, max. 28,8V).
24V
~20 m
~30 m
~40 m
~60 m
~100 m
~160 m
~240m
RACKMAX 650 230V
180, 230, 350, 550, 750, 1000 mm (*)
110-230v~ 50/60 Hz
0,45 – 0,22 A
)
N
)
~ 30-31 W
N
In accordance with length of truck run
115x42x(Course length+135) mm
Varies according to construction
Actuator fed at
110V~
~300 m
~450 m
~600 m
~900 m
~1500 m
~2500 m
~3700 m
32
RACKMAX 650 24V
600 N
7,5 mm/s
Class II
2 cycles
-5 +65 ºC
IP 42
Position self-regulating
Yes
Yes
3500 N
At absorption of power
At absorption of power
2 m (±5%)
~1400 m
~2100 m
~2800 m
~4000 m
~6800 m
~11000 m
~15000 m
24V
1,10 A
~ 27 W
7,6 mm/s
Class III (Selv)
5 cycles
with two cables
230V~