Notes prior to removal:
1. Before dismantling permanently disconnect the heating ele-
ment from the mains ensure that the radiator is not hot.
2. Be aware. a radiator filled with liquid can be very heavy. When
moving the radiator, ensure that you take the necessary safety
precautions.
3. Before disassembly, close the appropriate valves and drain
the radiator to avoid any damage being, close the appropri-
ate valves, drain the radiator, etc.) caused by water remaining
water inside the radiator.
Product disposal
This product should not be disposed of as general waste but should
be brought to the appropriate collection point for recycling of elec-
tric and electronic devices. This information is provided by the sign
on the product, user manual and packaging. Information on the
appropriate point for used devices can be provided by Your local
distributor or manufacturer of the product. Thank You for Your ef-
fort towards environment protection.
Manual
Specification
Power: 230 VAC
Insulation class: I
Ingress protection: IP67
Connection (type Z):
— Straight cable with plug and on/off switch
— Straight cable without plug (permanent connection to the elec-
trical system*)
* it must be possible to disconnect the device on all poles, by
points of contact with the clearance of 3 mm.
Radiator tapping: G 1/2"
The maximum pressure allowed in the radiator: 1.0 MPa
Rated power:
100
200
300
Length of el. heating element:
315
285
310
EN
400
600
800
345
375
485
1000 1200 1500 W
575
750
950
mm
27