8. The device should only be in-
stalled by a qualified installer
in accordance with the applica-
ble regulations regarding safe-
ty and all other regulations.
9. All installations to which the
device is connected should
comply with regulations appli-
cable in the country of installa-
tion and use.
10. Extension leads or electric plug
adapters should not be used in
order to supply power to the
heater.
11. While connecting the radiator
to electric installation ensure
that the curcuit has a 30 mA
residual-current circuit break-
er and an appropriate over-
current circuit breaker. With
the permanent installation (ca-
ble connection without plug)
it is also mandatory to have an
omni-pole cut-out for discon-
necting the device on all poles,
by points of contact with the
clearance of 3 mm.
12. The device equipped with
a supplying cable without plug
can be installed in bathrooms
in zone 1, as defined by appli-
18