ELECTRICAL CONNECTIONS
Accessory
Connections for 2
Bart 350 swinging
gate operators
Master
Slave
n°3 x 1.5
n°4 x 0.5
Elpro 35M
on Bart 350
Master
Accessory
Output for courtesy
lamp relay 24V 50mA
Pedestrian opening
on Bart 350 Master
NC safety contacts
in opening
pg.
26
to the
TERMINALS
Electrical connections
ATTENTION: the only electrical connections 3x1.5 and 4x0.5
between the two boards allow the Elpro 35 M programmer
to dialogue with the second Slave gate during programming
and operation.
All the accessories for command, signalling and safety must
be connected to the terminals of the Elpro 35M that manages
and controls the entire system.
3x1.5
4x0.5
Electrical connections
Output for courtesy lamp relay
max 24V 50mA
Common
NO input for external contact
for pedestrian opening on the
Bart 350 Master gate
Pedestrian
Common
All NC
receivers or of the safety edges
installed
to prevent crushing during
opening. In case an obstacle
is detected in opening, travel
direction is reversed, allowing
the removal of the obstacle, gate
stops and waits for a command.
and
THEIR FUNCTIONS
Motor 24V
Bart Slave
Motor
microprocessor
LED lamp
contacts of the photocell
must be in series
Instructions
Dip-switches and LED indication
of their functions
Refer to the previous pages for the
Dip-Switch arrangements relative to the
individual accessories and functions
The GREEN LEDs, in particular the LINK LED
on Elpro 35M, must be on: this confirms
proper communication between the Bart
Master and Slave on respective terminals
A-B-C-D
Bart Slave
release lever
FCA
= Bart Slave opening
switch
limit switch LED
FCC
= Bart Slave closing
limit switch LED
Elpro 35S
on Bart 350
Slave
For installation and
adjustment of limit switch
microswitches, see pg. 11
Dip-switches and LED indication
of their functions
L20 red
Off= lights up at every pedestrian
opening pulse
L21 green
On= NC contacts made.
It switches off whenever safety devices are
engaged
Bart Slave
limit switch
connector