ELECTRICAL CONNECTIONS
Accessory
Photocells:
internal external
Fit 55
Orbita 57
Key-switch:
Chis 37
Chis E 37
Radio Contact:
Receivers:
Astro 43
Jubi 433
Siti 63
Birio 868
DGT 61
Sape 69
main board
receiver
Warning Lamp
Output
24V- 1W:
24V Output:
24Volt dc Flasher:
24V AC/DC Output
for DSA control:
Photocell projectors
to the
TERMINALS
Electrical connections
Seen from inside the gate:
External photocells:
all NC contacts of external photocell receivers
must be connected in series to terminals 1 and
2: when obstructed, the gate will re-open, if in
closing phase
Internal photocells:
all NC contacts of internal photocell receivers
must be connected in series: when obstructed,
the gate is stopped in opening, closing and
pause until cleared.
NO and NC contacts to be connected to the
respective terminals of the key or button-
switches.
All the possible configurations are attached
to their respective command accessories
By connecting any NO contact to the two
terminals, each pulse can perform:
- Only opening:
Dip 2=ON and Dip 5=OFF
- Reverse direction on each impulse
Dip 2=OFF and Dip 5=OFF
RADIO
- Step by Step:
CONTACT
Open-Stop-Close-Stop
Dip 2=OFF and Dip 5=ON
Output for a possible automation status warning lamp:
Warning Lamp On= Gate Open
Warning Lamp Off= Gate Closed
Flashing at 0.5s (fast)= closing movement
Flashing at 1s (normally)= opening movement
Flashing at 2s (slowly)= automation stopped
24Vdc output for max load 500mA:
2 pairs of photocells
1 Radio receiver
1 Led key-switch Chis 37 / Chis E37 or DGT 61 board
All the instructions are attached to their respective
command accessories
24Vdc output for flasher
24Volt output for powering photocell projectors
(powered in parallel), for DSA control:
Device for Safety Autotest= before each movement
of the gate, if this function is enabled, all safety
accessories are checked to make sure that they are
free of obstacles, should they not, there is no start and
an error will be signalled on Bart 350 with a light that
turns to amber.
and
THEIR FUNCTIONS
DIP-SWITCH 1:
1
DIP-SWITCHES 2 and 5 (MUST NEVER be
simultaneously ON):
ON: Does not reverse and does not stop in opening
2
OFF: In opening always stops and reverses
ON: Step by step with intermediate stop
5
OFF: Reverses direction on every RADIO pulse
DIP-SWITCH 4 and 8:
ON: Pre-flashing before opening
4
OFF: without pre-flashing
ON: Flasher deactivated during Pause in
automatic operation mode (Dip 3 = ON)
8
OFF: Flashes during Pause in automatic mode
(Dip 3 = ON)
DIP-SWITCH 10:
ON: DSA control of the photocells. The photocell
projectors, outputs 13-14, must be powered
10
OFF: No DSA control on the photocells
Instructions
Dip-switches and LED indication
of their functions
ON: stops gate on opening and reverses it on
closing once obstacle is removed
OFF: no stop on opening, gate is reversed on
closing in case of an obstacle
L1 green On = no obstacle, it turns off in case
of obstacle
L2 green On = no obstacle, it turns off in case
of obstacle
L4 red Off = no contact OPEN, it lights up with
each opening pulse
L5 red Off = no contact CLOSE, it lights up with
each closing pulse
L6 green On = STOP contact closed, it turns off
by pulsing stop contact
L7 red Off= no RADIO contact, it lights up by
any radio contact pulse
pg.