REPLACEMENT OF PILOT LIGHT UNIT COMPONENTS (0*1FR3G-1*1FR4G)
To carry out this operation, proceed as follows.
Turn off the gas supply tap..
1)
Open the hatch (A).
2)
Cut the band clamp (B) and disconnect the
3)
cable (C).
Disconnect the gas supply line (D).
4)
Undo the screws (E) and remove the pilot light
5)
unit (F).
Undo the screws (G) and replace the ignition
6)
plug (H) and/or the body of the pilot light (L).
To replace the thermocouple (M) proceed as
follows.
Undo the screws (N) to remove the guard (P).
7)
Unscrew the union (Q) and replace the ther-
8)
mocouple (M).
Replace the guard (P).
9)
Reassemble the pilot light unit (F) and
10)
reconnect the gas supply line (D) and the
cable (C).
Close the door (A) when the operation is
11)
complete.
EQUIPMENT DECOMMISSIONING, DEMOLITION AND DISPOSAL
When decommissioning the appliance, a seri-
es of procedures must be carried out to ensure
that the appliance and its components are not a
hindrance and are not easily accessible.
To ensure that the appliance cannot constitu-
te hazards for people or the environment, all
energy sources (electricity, etc.) must be discon-
nected and rendered unusable, and any liquids
present must be drained (lubricants, fl uids, etc.).
Place the appliance in a suitable area which is
not easily accessible, with barriers to prevent an-
yone from accessing it.
When scrapping, sort all components by chemi-
cal characteristics and dispose of them separa-
3269850_inst_GB_rev.2
A
H
G E
tely in accordance with the relevant legal requi-
rements.
Important
Do not dump non-biodegradable products,
lubricating oils, and non-metallic compo-
nents (rubber, PVC, resins, etc.) in the envi-
ronment. Dispose of them in compliance with
the relevant laws.
- 17 -
L
B
M
C
F
D
P
N
Q
GB
ENGLISH