Adjusting Burner Primary Air (0*1Fr3G - 1*1Fr4G); Replacing Parts; Instructions And Warning For Replacing Parts; Replacement Of The Burner Nozzle - Angelo Po 0N1FR1G Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ADJUSTING BURNER PRIMARY AIR (0*1FR3G - 1*1FR4G)

To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Open the hatch (A).
2)
Undo the locking screw (B).
3)
Set the bush (C) at the distance as shown in
4)
the fi gure.
Tighten the screw (B).
5)
After making the setting, seal the screw with
paint.
Close the door (A) when the operation is
6)
complete.

INSTRUCTIONS AND WARNING FOR REPLACING PARTS

Important
Before carrying out any replacement proce-
dure, activate all the safety devices provided
and decide whether staff at work and those in
the vicinity should be informed.
In particular, turn off the gas supply tap and
prevent access to all devices which might
cause unexpected health and safety haz-
ards if turned on. If work parts have to be re-
placed, use original spare parts only.
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Open the hatch (A).
2)
Unscrew the nozzle (B) Unscrew the nozzle
3)
and replace it with the one suitable for the
type of gas in use (see table at back of manual).
Close the door (A) when the operation is
4)
complete.
3269850_inst_GB_rev.2

REPLACING PARTS

REPLACEMENT OF THE BURNER NOZZLE

A
The manufacturer declines all responsibly for
injury or damage to components due to the
use of non original parts, or extraordinary
work on the appliance which may modify the
safety requirements without the manufac-
turer's authorisation. When ordering compo-
nents, follow the instructions provided in the
parts catalogue.
A
- 15 -
B
B
ENGLISH