ADJUSTING BURNER PRIMARY AIR
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Open the hatch (A).
2)
Undo the locking screw (B).
3)
Set the bush (C) at the distance as shown in
4)
the fi gure.
Tighten the screw (B).
5)
After making the setting, seal the screw with
paint.
Close the hatch (A) when the operation is
6)
complete.
Importante
Important
Before carrying out any replacement procedure,
activate all the safety devices provided and de-
cide whether staff at work and those in the vicin-
ity should be informed. In particular, turn off the
gas supply tap, cut off the electricity supply us-
ing the master switch and prevent access to all
devices that might cause unexpected health and
GB
safety hazards if turned on. If worn parts have to
be replaced, use original spare parts only.
REPLACEMENT OF THE BURNER NOZZLE
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Open the hatch (A).
2)
Unscrew the nozzle (B) and replace it with
3)
the one suitable for the type of gas in use (see
table at back of manual).
Close the hatch (A).
4)
3269870_inst_GB_rev.2
REPLACING PARTS
INSTRUCTIONS AND WARNING FOR REPLACING PARTS
(0N1FR1ID-0T1FR1ID-1N1FR2ID-1T1FR2ID)
A
The manufacturer declines all responsibly for
injury or damage to components due to the
use of non original parts, or extraordinary
work on the appliance which may modify the
safety requirements without the manufactur-
er's authorisation.
When ordering components, follow the in-
structions provided in the parts catalogue.
(0N1FR1ID-0T1FR1ID-1N1FR2ID-1T1FR2ID)
A
- 14 -
B
C
29±1mm
B
B
ENGLISH