Configuration Of Settings; Configuring The Direct Panel; Configuring The Different Parameters - Fermax DUOX PLUS DIRECT CITY Manual De Instalador Y Programación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
Configuración de la Placa Direct.
The outdoor panel´s parameters can be programmed on the keypad.
For this you must enter in configuration mode via a programming access code after pressing
'A'.
Programming Access code: A + 4444 (default code).
If the code is correct, a confirmation tone sounds (beep-beep).
The parameters that can be configured are:
Position
Adjust Parameter
01
Time activ. lock releases
02
Time activ. exit button
03
Panel type
04
Block Nº
05
Sub-Block Nº
06
Panel Nº
07
Door sensor time
08
Opening code
09
Programming code
10
MASTER panel
11
Caretaker Mode
12
Monitor Volume
13
RESET settings

Configuration of settings

Introduce the two digits of its position, you will hear a beep and then you need to enter the desired value (1,
2, 3 or 4 digits, depending on the setting). If the value is correct you will hear a confirmation tone (beep-beep)
and the new value will have been saved. If it was incorrect you will hear the error sound (boop).
Position
+
Possible values
01...14 (beep)
1, 2, 3 or 4 digits (beep-beep)
Examples
09 (beep)
1128 (beep-beep)
01 (beep)
02 (beep-beep)
To leave the programming mode you need to press 'A' when introducing the position number of the
menu. It will also automatically exit after 60 seconds without the need to press any key, generating a
beep-beep tone.
Pag 44
Values [default]
Comment
01-99" [03]
Relay activation of lock releases from home or access control.
00-99" [06]
Relay activation of lock releases from exit button (terminals Bs y -)
0: Sub-Block
Configuration of panel type
[1]: Block
2: General Entrance
00-99 [00]
Block number belonging to the panel
00-99 [00]
Sub-block number belonging to the panel
0-9 [0]
Panel number
000-250
Maximum time that the door is allowed to remain
[000] inactive
open once activated
0000-9999
Opening code from the keyboard. The means of
[0000] inactive
entering the code: A + XXXX (4 digits)
0000-9999
Code to access programming
[4444]
[0]: No / 1: Yes
Activation of panel as master to programme home terminals
[0]: No Reset
Reset to night mode by entering "1" in this position
1: Reset
0-9 [5]
Adjust the volume of the panel monitor
[0]: No Reset
Return to default settings by entering a "1"
1: Reset
in this position
Comment
Digits depending on chosen setting
Change of programming code to 1128
Change of lock release activation time to 2
seconds
Tabla de contenido
loading

Este manual también es adecuado para:

73611

Tabla de contenido