General Information - CountyLine CL1800DC Manual Del Usuario

Sistema de batería de respaldo
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Safety • Specifications
Important Safety Instructions
SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation, operation, and maintenance of the product.
Save this manual for future reference.
This is the safety alert symbol. When you see this
symbol on your equipment or in this manual, look for
one of the following signal words and be alert to the
potential for personal injury!
indicates a hazard which, if not avoided, will
result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE addresses practices not related to personal injury.
Keep safety labels in good condition. Replace missing or
damaged safety labels.
1. To avoid risk of serious bodily injury due to electrical
shock or burns and property damage due to
flooding, read the safety instructions carefully before
installing pump.
Risk of burns. Battery posts, terminals
and related accessories contain lead and lead
compounds, chemicals known to the State of
California to cause cancer and reproductive harm.
Wash hands after handling.
Risk of explosion and hazardous gas.
Connect and disconnect DC output terminals only
after removing the charger from the AC outlet. Never
allow the DC terminals to touch each other.
Risk of electric shock. Can shock, burn
or kill. Do not plug in or unplug battery charger
while standing on a wet floor or in water. Be sure
one hand is free when plugging in or unplugging
charger. If basement floor is wet, disconnect power
to basement before walking on floor.
Risk of flooding. Can cause personal
injury and/or property damage. Do not run pump
dry. To do so will damage equipment.
2. Use this system only for backup sump pump duty
in a residential application. It is not designed as a
primary sump pump.
3. Follow local and/or national plumbing and electrical
codes when installing the system. A ground fault
Specifications -
Capacity Ratings with a 100 Ampere-Hour Deep Cycle Marine Battery
Gallons Per Hour
Aproximate Hrs Available
Total Gallons Pumped
* These flow rates were obtained with a constant 12.7 VDC battery source. The actual GPH will vary due to a reduction in output voltage from the battery as it discharges.
8' (2.4 m)
10' (3.0 m)
1,440
10
8,500
circuit interrupter (GFCI) is recommended for use on
any electrical appliance submerged in water.
4. Do not lift pump by electrical cord.
Risk of electric shock. Can shock, burn
or kill. Do not lift the pump by the electrical cord;
lift pump only by the discharge pipe, lifting ring or
handle on the pump. Lifting by the cord can damage
the cord.
5. Pump clear water only with this pump.
6. Pump is permanently lubricated at the factory. Do
not try to lubricate it!
7. Keep battery charger and battery box off of the floor
and in a dry, cool, well ventilated area.
Risk of hazardous gas. If a Carbon
Monoxide (CO) sensor is installed, it must be at
least 15 feet away from battery charger in order
to avoid nuisance CO alarms. Please refer to
your CO detector's installation instructions for
more information.
8. To avoid danger of fire or explosion, keep sparks and
flame (pilot light) away from battery.
9. Maximum vertical pumping distance is 16 feet (4.9m).
10. Make sure sump is clear of debris. Debris can
damage the pump which can result in flooding.

General Information

The battery back-up sump system is not a sub stitute for
your primary sump pump. It is designed to temporarily
back up your primary sump pump during a power outage
or other problem which prevents normal operation of
the primary pump. Do not use this system to pump
flammable liquids or chemicals. Pump clear water only
with this pump.
Keep the battery charger dry and protected from damage.
This system is designed to work with a deep cycle
marine battery, either a flooded lead-acid battery or
a sealed maintenance free lead-acid AGM battery. In
an emergency (such as an extended power outage)
which depletes the system deep cycle battery, your
automobile battery may be temporarily substituted. Be
sure to replace the system deep cycle battery as soon as
possible. Use of an automobile battery instead of a deep
cycle battery in this system will significantly reduce the
system's total performance. Automobile batteries are not
designed for this type of application and will be quickly
ruined by the repeated charge/discharge cycling.
Vertical Pumping Distance
12' (3.7 m)
1,200
11.5
7,000
16' (4.9 m)
840
No Flow at this Height
13
5,000
2
Tabla de contenido
loading

Tabla de contenido