Beretta Exclusive Green E C.S.I. Serie Manual Del Instalador página 19

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
INF2
It is possible to display information, which may be useful for the Technical Assistance Centre, by pressing the button
"INF2" appears on the display.
INF2 list
Step
Description
1
Input probe temperature
2
Return probe temperature
3
First sanitary probe temperature (*)
4
Not used in this model
5
Fumes probe temperature
6
Second heating system probe temperature
7
Domestic hot water flow rate (***)
8
Ventilator speed /100
9
Not used in this model
10
Not used in this model
11
Exchanger cleaning counter status
12-19
Historic alarm codes
Note (*): if the SAN probe is faulty or disconnected, in the place of the value "- -" is displayed.
(**): if the display also shows the dot (.), the temperature of the fumes probe is 100 + displayed value
(***): if the flow rate is >10 l/min A.x l/min appears on the display, where A=10 – B=11 – C=12
S.A.R.A. function (Fig. 22)
If the "winter" mode is selected, the S.A.R.A. (Automatic Ambient
Adjustment System) function can be activated.
Turn the heating water temperature selector to a temperature ranging
between 55 and 65°C.
The S.A.R.A. self-adjusatment system activates: depending on the
temperature set on the room thermostat and the time taken to reach it,
the boiler automatically adjusts the heating water temperature to reduce
operating times, thereby increasing operating comfort and energy saving.
Display 2 digits
xx
xx
xx
xx
xx (**)
xx
xx
xx
xx
xx
bH
xx
22
ENGLISH
for 10 seconds: the code
Display 4 digits
01
°C
02
°C
03
°C
Cond
°C
05
°C
06
°C
07
l/min
FAN
09
10
xxxx
HIS0-HIS7
19
Tabla de contenido
loading

Tabla de contenido