Before Initial Start-Up - Nederman FlexPAK 800 Manual De Instrucciones

Ocultar thumbs Ver también para FlexPAK 800:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 113
EN
FlexPAK 800/1000 DX
WARNING!
Work with electric equipment is to be carried out by a qualified electrician.
Personnel operating FlexPAK 800/1000 DX are to pay special attention to avoiding
discharge of static electricity. The requirements for the safe use and handling of
combustible dust are described in the explosion protection document. All personnel are
to be informed.
Do no start the unit without connecting and checking any disconnected grounding
points. See the Installation and Service Manual.
WARNING!
Use suitable protective equipment: goggles, ear protection and a protective mask.
A high vacuum system creates a powerful suction that may cause serious eye injury or
hearing impairment. Persons who will be using FlexPAK 800/1000 DX, or may come in
contact with FlexPAK 800/1000 DX, are to be informed about this risk.
Never look into the exhaust air duct. Debris and particles coming out of the outlet may
cause eye injury.
Use proper protective equipment when risking exposure to dust.
Never operate the unit without an antistatic plastic sack in the dust bin if the dust is
hazardous.
The outlet silencer and fan may reach high temperatures during normal operation.
CAUTION!
Read and follow all instructions in the Installation and Service Manual before use.
NOTE! Some materials may undergo chemical reactions in combination with humidity/
water. Such humidity may, for example, form if the humidity in the extracted air is
condensed in the filter.
5.1

Before initial start-up

NOTE! The unit is NOT to be operated under any circumstances without directing the
exhaust air away from the unit.
It is important that no dust, objects or debris are allowed to fall down into either the inlet
or outlet of the side channel fan.
The unit with its accessories are tested before delivery, and all functions are checked.
Before initial start-up ensure the following:
The maintenance switch has been installed, see figure 9 item 10.
The room where the unit is located, if small, has adequate ventilation. See the
Installation and Service Manual.
The ducting is connected to the dust collector inlet.
An exhaust air duct is attached to the outlet to direct hot exhaust air away from the
unit.
The compressed air supply is permanently connected. Idle mode and the filter
cleaning will not work properly without a compressed air supply.
The PS cable is connected, but no valves at work sites are open.
Make sure that the ground check measurement has been performed. See the
Installation and Service Manual.