7.2
Parameter settings
To change individual parameter settings, see the PLC Settings Manual. Below are parameter
settings discussed in section '5 Use'.
7.2.1
SSR_Time
Menu for setting the SSR timer. The SSR timer is for the amount of time before the unit
goes from Idling mode to Standby mode when the pilot signal disappears.
SSR_Time
1/1
T
= 10:00m
Ta = 00:00
ESC
OK
7.2.2
DIR_Time
Menu for setting the DIR timer. The DIR timer is the amount of time before the unit goes
from Running mode into Idling mode when the pilot signal disappears.
DIR_Time 1/1
T
= 10:00s
Ta = 00:00s
ESC
OK
7.2.3
Weekly timer
Weekly timer sets the unit to "Stand By" mode and "Off Mode" at preset times. If the pilot
signal "PS" is active and the Vacuum unit is in Standby mode, the unit starts.
WeekTmr
1/2
D1
= - - - - - - -
On1
= -- : --
Off1
= -- : --
D2
= - - - - - - -
On2
= -- : --
ESC
OK
T=12:00 minutes: Time before SSR_Time is activated. The default
setting is 12 minutes. The minimum setting is 5 minutes.
Ta=00:00 minutes: The elapsed time since the pilot signal disappeared.
T=10:00 seconds: Time before DIR_Time is activated. The default setting
is 10 seconds The minimum setting is 5 seconds.
Ta=00:00 seconds: The elapsed time since the pilot signal disappeared.
FlexPAK 800/1000 DX
EN
31