Roof Exhaust With Traditional Fireplace - Palazzetti ecofire giorgia Manual De Uso Y Mantenimiento

Ocultar thumbs Ver también para ecofire giorgia:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Anchor the pipes with suitable collars to the wall.
The fume exhaust connection must not be connected:
to a fireplace used by other generators (boilers,
stoves, fireplaces, etc.);
to air extraction systems (hoods, vents, etc.) even
if "intubated".
It is forbidden to install shut-off and draft valves.
The exhaust of the combustion products must be
provided on the roof.

12.5.1 Roof exhaust with traditional fireplace

The flue for flue gas discharge must be carried out
in compliance with the UNI 10683- EN 1856-1-2- EN
1857- EN 1443- EN 13384-1-3- EN 12391-1 standards both
regarding the dimensions and the materials used in
its construction.
Ramshackle flues, made of unsuitable material (fibre
cement, galvanised steel, etc. with rough, porous
inner surfaces) are illegal and prevent the stove from
working correctly.
The discharge of fumes through a traditional fireplace
(Fig. 5.5.1a) can take place provided that the chimney
is maintained;
If the chimney has a larger section, it must
be "intubated" with a suitably insulated
steel pipe (with diameter suitable for the
route) (Fig. 5.5.1b).
Make sure that the connection to the brickwork
chimney is properly sealed.
In case of the passage of pipes through
wooden roofs or walls, it is advisable to
use dedicated certified and commercially
available crossing kits.
28
A) Windproof cowl
B) Seal
C) Inspect
2
1) Vermiculite and/or mineral wool.
2) Steel piping.
3) Closure panel.
Fig. 5.5.1a
1
3
Fig. 5.5.1b
004778270 - 24/07/2020
Tabla de contenido
loading

Tabla de contenido