Technical Characteristics; Diagnostics Led; Terminal Board Connections - tau K892M Guía Para La Instalación

Ocultar thumbs Ver también para K892M:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

controls using RELAYS or using our 750T-RELE device.
2. TESTING
When you have completed the connection:
All the green LEDs must be on (each of them corresponds to a Normally Closed input). The go off only
when the controls to which they are associated are operated.
The red DL5 LED must be off (corresponding to the Normally Open OPEN/CLOSE input). It only comes
on when it is activated by the control to which it is associated.
The red DL7 LED must be on (giving indications during the programming of the radio control device).

3. TECHNICAL CHARACTERISTICS

Power input to board
Max motors nominal power
Fast acting fuse for protection of auxiliary circuits 24 V dc (F1 - 5x20)
Input voltage of motor circuits
Input voltage of auxiliary circuits
Fast acting fuse for protection of input power supply 230 Vac (F2 - 5x20)
Working temperature

4. DIAGNOSTICS LED

DL1
SENSITIVE EDGE green LED signal
DL2
OPEN LIMIT SWITCH green LED signal
DL3
CLOSE LIMIT SWITCH green LED signal
DL4
External input STOP green LED signal (terminal 17)
DL5
OPEN/CLOSE button red LED signal
DL6
PRESSURE-SENSITIVE EDGE green LED signal
DL7
RECEIVER PROGRAMMING INFORMATION and ERRORS red LED signal
DL8
Integrated push button panel Stop green LED signal

5. TERMINAL BOARD CONNECTIONS

Terminals Function
1 - 2
POWER SUPPLY
3 - 4
COURTESY LIGHT
5 - 6
FLASHING LIGHT
7 - 8
AERIAL
9 - 10
2
RADIO CH
nd
11 - 12
AUX 24V AC
PRESSURE-
13 - 15
SENSITIVE EDGE
Description
Power input 230Vac, 50Hz, single-phase; 1 = Phase; 2 = Neutral;
Output for auxiliary courtesy light 230 Vac;
Flashing light output 230 Vac 20 W max.
433,92 MHz built-in RX aerial input; 7 = Earth 8 = Signal;
2
radio channel output;
nd
Warning: to connect other devices to the 2nd Radio Channel (area
lighting, pumps, etc.), use an additional auxiliary relay.
24 Vac output for powering safety and/or other devices (photocells, re-
lays for lighting, etc);
Pressure-sensitive edge input; 13 = Pressure-sensitive edge; 15 = Common.
If the resistive sensitive edge is not used, do not short circuit terminals 13
and 15. The input is only excluded by means of dip 9;
Note: if the resistive sensitive edge is used, to install the electric resist-
ance provided as shown in enclosed instruction.
5
230V AC - 50 Hz
400 W
F 500 mA
230V AC
24V AC
F 6,3 A
-20°C ÷ +55°C
Tabla de contenido