10. Assembly
Warning!
Only operate the fitting with the specified filters.
Failure to observe this instruction can result in an increased germ load in the
drinking water and thus pose a health or mortality risk.
Warning!
• Operate the product only with safety extra low voltage (SELV). The components
do not have to be earthed.
• Secure the electrical connection with a residual current circuit breaker (RCD).
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
☞
Important!
Prior to the assembly process, flush the pipework in accordance with DIN 1988.
10.1 Establish the water connection.
☞
Take note of the flow direction.
10.2 Align the water quantity regulator so that the operating elements point forwards.
10.3 Open the water quantity regulator.
a: closed
b: open
10.4 Flush the pipes according to DIN 1988.
10.5 Close the water quantity regulator.
10.6 Open the locking screw (c) of the water quantity regulator.
☞
Important!
Note the installation position of the filter.
10.7 Inset the filter (d).
10.8 Insert the locking screw.
10.9 Remove the flush connector (e).
☞
Take note of the flow direction.
10.10 Insert the solenoid valve (f) with the seals.
10.11 Install a switch box (not part of the delivery scope) at a height of approx. 1200 mm.
10.12 Install an empty conduit (not part of the delivery scope; Ø
the switch box.
☞
To protect the tiles, use masking tape when marking and drilling.
10.13 Hold the cover plate with the piezoelectric button at a height (g) of approx. 1200 mm
against the wall.
10.14 Mark the drill holes.
6
= at least 20 mm) to
inside