The batteries are accessed by removing the display as
described in the section showing how to rotate the display.
The Battery Foam may be stuck to the batteries. Carefully
remove it and reinstall at assembly. The Battery Foam
protects the batteries and prevents them from becoming
dislodged if the meter is handled roughly.
Pay attention to the polarity of the batteries as marked
inside the battery holder. The meter will not operate if the
batteries are installed incorrectly and damage may occur.
WARNING!
To reduce the risk of explosion DO NOT mix old
batteries with new batteries, or mix batteries of
different manufacturers.
Batteries may ONLY be replaced with the following:
• Duracell MN1500
• Duracell QU1500
Maintenance and Storage
If the meter will be stored for an extended period of time
without use and is being used with a fluid that may leave
a residue, it should be flushed with a compatible fluid to
prevent sticking and binding of the turbine assembly.
The exterior of the meter may be wiped down with a mild
water based detergent and damp cloth to clean the display.
Do not use a power washer to clean the meter.
CAUTION!
To reduce the risk of ignition due to electrostatic
discharge, avoid contact with the electronic hous-
ing. Clean only with a damp cloth.
IMPORTANT!
Use of compressed air WILL cause permanent
damage to the meter and void the warranty. Always
use a gentle stream of compatible fluid to rinse the
interior of the meter.
• Energizer E91
Safety Testing Approvals
The Fill-Rite TT10 Series meters have been tested
for compliance to the standards set forth by
Underwriters Laboratories (UL), UL Canada, ATEX,
and other testing organizations. To determine which
specific compliances apply to your particular
meter, refer to the faceplate for information and
compliance logos.
FLOW METER FOR HAZARDOUS LOCATIONS
Exia INTRINSICALLY SAFE (SECURITE
INTRINSEQUE) Class I, Group D, T4; Class I, Zone
0, AEx ia IIA T4 Ex ia IIA T4; IECEx UL 16.0147X;
Ex ia IIA T4 Ga;
-40°C < Ta < +60°C
II 1G
Ex ia IIA T4 Ga
DEMKO 16 ATEX 1787X
CE Certification Information
The TT10 Series meters bearing the CE mark
have been certified to the following European
directives:
2011/65/EU: Restriction of the use of certain
hazardous substances in electrical and electronic
equipment. 2014/30/EU: Electromagnetic
Compatibility
The following standards were used to test and
show compliance:
Emissions
EN 55011:2009/A1:2010 Group 1, Class B, Industrial,
Scientific, and Medical (ISM) Equipment
Immunity
EN 61326-1:2013, Electrical Equipment for
Measurement, Control and Laboratory Use
IEC 61000-4-2: 2009 ESD
IEC 61000-4-3: 2006 A1:2008 & A2:2010 Radiated
Immunity
IEC 61000-4-8: 2010 Magnetic Field
EN 60079-0: 2012 + A11:2013
IEC 60079 Edition 6
EN 60079-11: 2012
IEC 60079-11 Edition 6
UL60079-0 Sixth Edition
UL60079-11 Sixth Edition
CAN/CSA - C22.2 No 157-92
CAN/CSA - C22.2 No 60079-0:2014
CAN/CSA - C22.2 No 60079-11:2015
5
Regulatory