Start, Control, And Adjustment Of The Temperature - Oscartielle POLARIS D Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Power
line
i
Automatic
safety switches
instruct the operator on the position of the switches to be reached quickly
Cabinets with
built-in unit
Before
connected
i
If the electrical supply is interrupted, the electrical equipment of the shop will not restart,
triggering the overload protection devices; modify the system to differentiate the
enablement of the various devices.

14. Start, control, and adjustment of the temperature

Cabinets with
the cooling temperature is controlled by means of:
remote unit
- electronic controller (Fig. 15)
i
Cabinets with
Procedure:
built-in unit
Step
1
2
3
4
5
i
05060144 01 22/08/2014
the supply lines of the electric energy should meet the requirements of
power consumption of the cabinet(cap.9.).
check that the power line:
- has wires with suitable cross section
- is protected against over-current and dispersions toward earth in
accordance with the rules in force
for the power supply lines measuring more than 4-5 m, increase the
section of the cables appropriately.
The replacement of the power cord is reserved to the manufacturer or
a body authorized by the same.
protect the upstream cabinets with omnipolar circuit breakers with
suitable characteristics that will also have the function of master switches
for cutting off the line
in case of EMERGENCY
DANGER! Live parts. Short circuit. Emergency.
The circuit breakers must not open the circuit on neutral point
without opening it simultaneously on phases and, however, must
allow complete cut off in overvoltage conditions category III
the cabinets are preset for plug connection (NOT SUPPLIED)
install a suitable plug of suitable capacity, compliant with regulations in
force and observe the safety rules:
yellow-green = ground / light blue = neutral / brown-black = phase
the electrical cable must be stretched to avoid damaging it or endangering people
DANGER! Live parts. Short circuit. Emergency.
Do not use sockets already connected to other users, nor reducers,
pins or multiple sockets.
consult the wiring diagrams annexed to the cabinet before wiring
check that power supply voltage is the one reported on the rating plate.
remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
proceed with wiring
The controller is set in the factory during testing.
To change the set parameters, contact the manufacturer.
cut off power to power plug (Fig. 14).
insert the plug and restore power.
close the main switch of the electric panel (Fig. 14) 1.
Result: The cooling system starts functioning immediately.
after about 60 minutes of operation with the cabinet empty,
check the temperature.
if the temperature has reached the storage values
introduce the goods.
Load the goods cooled at storage temperature
Polaris D - Mini Polaris D
Action
English
57
Tabla de contenido
loading

Tabla de contenido