with a cardboard casing (on request) (Fig. 6).
in wooden crate (on request) (Fig. 7).
The
comply with the local standards in force
installation
comply with the environmental climatic class (cap.9.)
area should
have a floor able to support the weight of the cabinet
a switch with automatic protection against short circuits, ground discharges
and dispersions between the electric power line and the machine;
have the space needed for use and maintenance
Environment
For a correct operation of the cabinet, the room temperature and relative
humidity must not exceed the limits relative to climatic class 3 (+25°C; R.H.
al conditions
60%) established by the norms EN-ISO 23953 - 2 with which the counter has
been tested.
Cabinet
make sure the packing is intact and that it does not display readily apparent
damages;
delivery
carefully perform the unpacking operation in order not to damage the
cabinet;
check that cabinet components are intact
should you notice any damage immediately inform the manufacturer
Installation
Step
procedure
POLARIS D
1
2
3
4
6
7
8
9
Installation
Step
procedure
Mini Polaris D
1
2
3
4
6
7
8
9
10
05060144 01 22/08/2014
carefully examine the installation area, eliminating any danger to the
operator;
remove the package only if the cabinet is placed in the operation
area
remove the fastening screws from the wooden frame (Fig. 8)
remove the wooden frame
install and adjust the regulation feet at a maximum height of 25 mm
(Fig. 8)
adjust the horizontal position of the cabinet using a spirit level (Fig. 10)
bend the cabinet backwards
check that all feet are into contact with the floor
carefully examine the installation area, eliminating any danger to the
operator;
remove the package only if the cabinet is placed in the
operation area
remove the fastening screws from the wooden frame (Fig. 8)
remove the wooden frame
install and adjust the regulation feet at a maximum height of 25 mm
(Fig. 8)
adjust the horizontal position of the cabinet using a spirit level (Fig. 10)
bend the cabinet backwards(Fig. 12)
check that all feet are into contact with the floor
secure the cabinet with the anchoring brackets supplied (Fig. 11)
use anchor plugs (not provided) suitable for the type of wall or
floor.
Polaris D - Mini Polaris D