BTL7-P511-M _ _ _ _ -J-DEXC-TA12
Magnetostrictive Linear Position Sensor – Rod Style
7
Technical data (continued)
7.5
Dimensions, weights
Rod diameter
Nominal length
Weight (depends on
length)
Housing material
Flange material
Rod material
Rod wall thickness
Housing mounting
7.6
Connection to the evaluation unit
The maximum sampling rate f
value is available with each sampling, can be found in the
following graphic:
f
in Hz
A,max
Fig. 7-1:
Maximum sampling rate depending on the nominal length
20
english
10.2 mm
25...7620 mm
Approx. 3 kg/m
Stainless steel
Stainless steel
Stainless steel
2 mm
Flange with 6 holes
, at which a new current
A,max
Nominal length in mm
Ignition protection "d"
Flameproof enclosure
The minimum sampling rate f
A,min
is 62.5 Hz.
(1) 1 magnet
(2) 2...16 magnets