BML SF2-I2 _ _ -GZZZ - ZZZ5-...
Incremental Magnetic Encoder System
9
Type code
S
= Sensor head
Construction:
F2
Pole width:
2
= 2 mm
Reference signal:
0
= no signal
1
= single signal (or fixed-periodic)
2
= pole-periodic signal
Alignment:
1
= longitudinal
2
= lateral
Interface:
G
= Analog Sin/Cos (1 Vpp) for functional safety
Operating voltage:
5
= 5 V DC
Electrical connection:
Cable
KA_ _ = PUR, shielded, standard, possible cable lengths 2, 5, 10, 15, 20 m (KA05 = 5 m cable)
KD_ _ = PUR, shielded, for drag chain, possible cable lengths 2, 5, 10, 15, 20 m (KD05 = 5 m cable)
KF_ _ = PUR, shielded, for fixed routing, possible cable lengths 2, 5, 10, 15, 20 m (KF05 = 5 m cable)
Cable with connector
KA00.3-S284 = PUR, shielded, 0.3 m cable length, with M12 plug
www.balluff.com
BML SF2 - I201 - GZZZ - ZZZ5 - KA05
english