Cuadro electronico de mando para uno o dos motores
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G G
B B
ACCESSORIES -
E
XPANDER 24V CARD
!! FEED THE EXPANDER 24V CARD IN WHEN POWER IS NOT SUPPLIED
!!
- PEDESTRIAN OPENING COMMAND
- CLOSURE COMMAND AFTER PASSING THROUGH THE PHOTOCELLS
- 24Vac ACCESSORIES FEEDING
- STRIP CONTROL IN OPENING AND CLOSING
- CONNECTABLE TO TRAFFIC LIGHTS
- CONNECTABLE TO BOX LIGHT
E
XPANDER PLEX 24V CARD
- PEDESTRIAN OPENING COMMAND
- 24Vac ACCESSORIES FEEDING
- STRIP CONTROL IN OPENING AND CLOSING
- PHOTOCELLS AND STRIPS AUTOTEST
- CONNECTABLE TO TRAFFIC LIGHTS
- CONNECTABLE TO BOX LIGHT
C
ODE LEARNIG SYSTEM RADIORECEIVERS
RX91/A
quarzata and coupling
RX91/A
quarzata and terminal board
RX433/A
super eterodyne and coupling
RX433/A
super eterodyne and terminal board
RX433/A 2CH super eterodyne, 2 channel and coupling code ACG5051
RX433/A 2CH super eterodyne, 2 channel and terminal board
For the connections and the technical data of the optional equipments follow the relevant
handbooks.
code ACG5471
code ACG5473
code ACG5005
code ACG5004
code ACG5055
code ACG5056
code ACG5052
B
ATTERY CHARGE CARD
The time needed to completely charge the 12Vdc 2,2Ah batteries (n° 2
batteries connected in series, optional cod. ACG9515), upon first
installation, is 24 hours, with a charging current of 0.03A.
POWER SUPPLY GATE OPEN INDICATOR AND STATE OF
BATTERY (COM-SIGNAL)
This indicator, in addition to signalling that the gate is open, emits 2
brief flashes followed by a pause of 2 seconds when the gate is closed
and there is no power supply, indicating that it is functioning with the
battery.
Functioning of the gate is guaranteed up to a charging level of
approximately 20V, following which the gate blocks and the indicator
flashes continuously to signal that the battery is low.
Only when voltage returns will the indicator go out and all the controls
be restored (obviously the battery will only recharge when there is
voltage).
N.B.: If you overdo the leds, the board's circuit will suffer from this, with
a possible block of the operations.
FUNCTIONING IN A BLACKOUT (WITH BATTERIES)
If batteries are connected to the control unit, when there is a power cut
the functioning of the gate is guaranteed up to a charging level of
approximately 20V, following which a signal is sent by the recharge card
to the control unit which blocks the gate and makes the battery signal
light flash.
Once voltage returns we recommend that the gate be fully opened.
Allow the gate to close by itself with automatic closure or wait for the
flashing light to stop before giving the command to close.
This operation will allow the gate to realign itself. In fact, if during the
blackout the motors were released and moved from the normal closing
position, the first manoeuvre when the power supply returns must be
complete.
During this phase the safety devices are active.