RIB KS2 24V Manual Del Usuario página 22

Cuadro electronico de mando para uno o dos motores
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G G
B B
RADIO TRANSMITTER
DIP4 - OFF => It cyclically commands open-stop-close-stop-open-etc.
DIP4 - ON => It opens the gate when this is closed. If It Is operated
while the gate Is opening, It has no effect. If It Is
operated when the gate Is open, It closes. If It Is
operated while the gate Is closing, It opens the gate
again.
AUTOMATIC CLOSING
Pause times before the automatic closing of the gate are set with the
timing procedure.
The maximum pause time Is 5 minutes.
Pause time can be started or stopped by DIP3 (ON started).
Pedestrian pause time can be started or stopped by DIP9 (ON started).
ELECTRIC LOCK
Set Dip11 to ON to enable control of the electric lock in the opening
phase.
RELEASE PULSE IN OPENING PHASE
Set Dip10 to ON to enable the release pulse of the electric lock in the
opening phase (provided Dip11 is set to ON)
With the gate closed, pressing an opening command will cause the gate
to perform the closing movement for 0.5s (in this phase the Encoder(s)
is/are not enabled), and simultaneously the electric lock is activated
(followed by 0.5s pause and then by opening of the gate).
GATE LEAF RELEASE ASSIST:
With the electric lock release pulse active (Dip10 - ON), when the gate
is closed a direction reversal manoeuvre is performed for a fixed time
of 0.2s to facilitate manual release (in this phase the Encoder is not
enabled).
OPERATION AFTER BLACK-OUT
When mains electrical power is restored press the opening button (K,
OPEN, radio).
The gate will open. Let the gate close itself with automatic closure or
wait that the flasher stops blink first to command the closing movement.
This operation is valid to obtain the leaves position readjustment.
During this phase all safety devices are active.
INTRUSION ALARM MODE (ABIS System)
ABIS facility (Anti Break-in System) is available only in operator
PRINCE 24V PLUS (DIP 12 ON position) with encoder proper
connected (DIP 7 ON or OFF position).
Operation: only with gate completely closed, in case of manual forcing
of the shutters, the motor/s are selected to close, preventing access. In
the meantime the output to SIREN is enabled, and remains activated for
7 sec .
In case the intrusion prevention mode is enabled, all commands are
inhibited, hence the gate can be selected open only after 7 sec.
Should the motor work without ABIS facility, it is advisable to instal an
electrical lock to ensure an efficient locking of the gate.
SIREN (-
+)
Current supplied for siren operation (300 mA max, 12Vdc)
It is possible to install a siren (code ACG2278) to monitor the manual
forcing of the gate and thus the intrusion of unauthorized persons.
Siren facility is available only in operator PRINCE 24V PLUS (DIP 12
ON position) with encoder proper connected (DIP 7 ON or OFF
position).
S
AFETY ACCESSORIES OPERATION
ENCODER
It serves as a safety device both during opening and on closure,
with movement reversion. DIP 7 (ON) OPERATES THE MOTOR
WITH ENCODER.
If You move DIP 7 OFF, You have also to move jumpers JP1 and
JP2 in up position (refer to previous page point C).
Jumper position for PRINCE with Current sensors
DIP 7 OFF - Current sensors On / Encoder Off
Jumper position for PRINCE with Encoder
DIP 7 ON - Current sensors Off / Encoder On
If the Encoder does not work (due to a failure In the power supply,
disconnected wires, broken or defective disk), the gate Is not operated.
If the encoder operates the closing or the opening and than gives a
reverse command, the gate stops and reverses Its movement for 1
second. If linked, the buzzer buzzes to alarm for 5 minutes and the
blinker blinks for 1 minute.
During or after the 5 minutes, when the buzzer alarms, you can make
the gate work again just pressing the operating button you want.
PHOTOCELL 1 (COM-PHOT 1)
If DIP 6 is OFF => The gate does not open if there is an obstacle within
the photocells range of action. During operation,
photocells work both when the gate opens (by
starting the opening movement again after half a
second time), and when it closes (by starting the
reverse movement after one second time).
If DIP 6 is ON => If there is an obstacle within the photocells range of
action when the gate is closed and its opening is
commanded, the gate opens (during Its opening,
photocells do not work). Photocells work only while
the gate Is closing (by starting Its reverse motion
after one second, even if they are still engaged).
STOP BUTTON
The STOP button stops the gate during any operation.
If you push it when the gate is totally open (or partly open, by using the
pedestrian command), this button temporary excludes the automatic
closing (if selected by DIP3 or DIP9). It Is than necessary to operate
another command to make the gate close again.
The automatic closing function Is enabled again with the following
operating cycle (if selected by DIP3 or DIP9).
BLINKER
N.B.: This electric board can supply power ONLY TO BLINKERS
WITH BLINKING CIRCUIT.
Use flasher (ACG7061) with lamp 24V 20W max.
PRE-BLINKING FUNCTION:
DIP 8 - OFF => the motor, the blinker and the buzzer start at the same
time.
DIP 8 - ON => the blinker and the buzzer start 3 seconds before the
motor.
BUZZER (Optional)
Current as supplied for buzzer operation 200 mA 12Vdc
The buzzer emits an intermittent sound signal during opening and
closing cycles. When safety devices are operated (alarm), the
intermittence frequency of this sound signal Increases.
WARNING LIGHT - GATE OPEN (COM-SIGNAL):
Its function Is to signal when the gate Is open, partly open or not totally
Tabla de contenido
loading

Tabla de contenido