Electrical Connection; Electrical Requirements - U.s.a - Sears Kenmore Elite 66442783710 Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
Be sure that the electrical connection and wire size are
adequate and in conformance with the National Electrical
Code, ANSI/NFPA 70-latest edition and all local codes
and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as
to whether the appliance is properly grounded. Do not modify
the power supply cord plug. If it will not fit the outlet, have a
proper outlet installed by a qualified electrician.

Electrical Connection

To properly install your range, you must determine the type
of electrical connection you will be using and follow the
instructions provided for it here.
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial/rating
plate. The model/serial/rating plate is located on the
right vertical surface of the oven door frame. Refer to
the illustrations in the "Product Dimensions" section of the
"Location Requirements" section.
Electrical Requirements – U.S.A.
This range is manufactured with a 4-wire power supply
cord rated at 240 volts, 40 amps, rated at 194°F (90°C)
and investigated for use with this range.
Range Rating*
120/240 Volts
120/208 Volts
8.8 - 16.5 KW
7.8 - 12.5 KW
16.6 - 22.5 KW 12.6 - 18.5 KW 50
* The NEC calculated load is less than the total connected
load listed on the model/serial/rating plate.
When a 4-wire, single phase 240 volt, 60 Hz., AC only
electrical supply is available, a 40-amp minimum circuit
protection is required on 30" (76.2 cm) ranges, fused on
both sides of the line.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a UL or CSA International
Certified Power Cord intended to be plugged into a
standard 14-50R wall receptacle. Be sure the wall
receptacle is within reach of range's final location.
Do not use an extension cord.
The wiring diagram is located on the back of the range or
in a clear plastic bag.
Specified Rating of
Power Supply Cord Kit
and Circuit Protection
Amps
Temp Rating
40 or 50
194°F (90°C)
194°F (90°C)
9
Tabla de contenido
loading

Este manual también es adecuado para:

Kenmore elite 66442793710

Tabla de contenido