Electrical Requirements – Canada
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine
that the ground path is adequate and wire gauge are in
accordance with local codes.
Be sure that the electrical connection and wire size are
adequate and in conformance with CSA Standard C22.1,
Canadian Electrical Code, Part 1—latest edition, and all local
codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
Range Rating*
120/240 Volts
120/208 Volts
8.8 - 16.5 KW
7.8 - 12.5 KW
16.6 - 22.5 KW 12.6 - 18.5 KW 50
* The CEC calculated load is less than the total connected
load listed on the model/serial/rating plate.
A circuit breaker is recommended.
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach
of range's final location.
Do not use an extension cord.
The tech sheet and wiring diagram are located on the back
of the range in a plastic bag.
10
Specified Rating of
Power Supply Cord Kit
and Circuit Protection
Amps
Temp Rating
40 or 50
194°F (90°C)
194°F (90°C)
Gas Supply Requirements – For Dual
Fuel Models Only
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local
codes and ordinances. In the absence of local codes,
installation must conform with American National Standard,
National Fuel Gas Code ANSI Z223.1 - latest edition or
CAN/CGA B149 - latest edition.
IMPORTANT: Leak testing of the range must be conducted
according to the manufacturer's instructions.
Type of Gas
Natural Gas:
This range is factory set for use with Natural gas. See the "Gas
Conversions" section. The model/serial/rating plate located on
the oven frame behind the top left-hand side of the oven door
has information on the types of gas that can be used. If the
types of gas listed do not include the type of gas available,
check with the local gas supplier.
Propane Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the
gas specified on the model/serial/rating plate for use with a
different gas without consulting the serving gas supplier. See
the "Gas Conversions" section.