Adjust Flame Height - Sears Kenmore Elite 66442783710 Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Adjust Surface Burner Flame
Adjust the height of top burner flames. The cooktop low burner
flame should be a steady blue flame approximately 1/4"
(6.4 mm) high. Propane gas flames have a slightly yellow tip.
A
B
A. Low flame
B. High flame
To Adjust Standard Burner:
The flame can be adjusted using the adjustment screw in the
center of the valve stem. The valve stem is located directly
underneath the control knob.
If the Low Flame Needs to Be Adjusted:
1. Light 1 burner and turn to lowest setting.
2. Remove the control knob.
Hold the knob stem with a pair of pliers. Use a small
flat-blade screwdriver to turn the screw located in the
center of the control knob stem until the flame is the proper
size. Turning the screw clockwise will increase the flame size
and counterclockwise will decrease the flame size.
A
A. Control knob stem
B. Screwdriver
C. Pliers
3. Replace the control knob.
4. Test the flame by turning the control from the low position
to the high position, checking the flame at each setting.
5. Repeat the previous steps for each burner.

Adjust Flame Height

B
C
To Adjust Double Burner (on some models):
1. Light burner and turn to lowest setting where both inner
and outer burners are lit.
2. Remove the control knob.
3. Insert a 1/8" (3 mm) flat-blade screwdriver into the
adjustment locations shown in the following illustration
and engage the slotted screw. Turn the screw until the
flame is the proper size. Turning the screw clockwise
will increase the flame size and counterclockwise will
decrease the flame size.
A
A. Control knob stem
B. Screwdriver
C. Pliers
4. Replace the control knob.
5. Test the flame by turning the control from Low to High,
checking the flame at each setting.
B
C
27
Tabla de contenido
loading

Este manual también es adecuado para:

Kenmore elite 66442793710

Tabla de contenido