1. Remove cooktop burner caps and bases from package
containing parts. Place the burner bases as indicated
by the following illustration:
A
B
A. Small
B. Large
2. Align the gas tube opening in the burner base with the
orifice holder on the cooktop and the igniter electrode with
the notch in the burner base.
E
A. Burner cap
B. Gas tube
opening
3. Place the burner caps on the appropriate burner bases.
IMPORTANT: The bottom of the small and medium caps
are different. Do not put the wrong size burner cap on the
burner base.
Small cap
22

Complete Installation

C
D
C. Medium
D. Large
A
B
C
D
C. Burner base
D. Igniter electrode
E. Orifice holder
Medium cap
Large cap
Burner caps should be level when properly positioned. If burner
caps are not properly positioned, surface burners will not light.
The burner cap should not rock or wobble when properly
aligned.
A. Incorrect
B. Correct
4. Place burner grates over burners and caps.
5. Plug into grounded outlet. See the appropriate
"Electrical Requirements" section.
6. Check that all parts are now installed. If there is an extra
part, go back through the steps to see which step was
skipped.
7. Check that you have all of your tools.
8. Check that you have all of the range accessories, especially
oven racks. These accessories may be in the range
packaging.
9. Dispose of/recycle all packaging materials.
10. Check that the range is level. See the "Level Range"
section.
11. Use a mild solution of liquid household cleaner and warm
water to remove waxy residue caused by shipping material.
Dry thoroughly with a soft cloth. For more information, see
the "Range Care" section of the Use and Care Guide.
12. Read the Use and Care Guide.
13. Turn on surface burners and oven. See the Use and Care
Guide for instructions on range operation.
NOTE: Odors and smoke are normal when the oven is used
the first few times.
If Range Does Not Operate, Check the Following:
Household fuse is intact and tight, or circuit breaker has not
tripped.
Gas pressure regulator shut-off valve is in the open position.
Range is plugged into a grounded outlet.
Electrical supply is connected.
IMPORTANT: If the range control displays an "F9" or
"F9, E0" error code, the electrical outlet in the home may
be miswired. Disconnect power and contact a qualified
electrician to verify the electrical supply.
14. When the range has been on for 5 minutes, check for heat.
If the range is cold, turn off the range and check that the
gas supply line shut-off valve is open.
If the gas supply line shut-off valve is closed, open it,
and then repeat the 5-minute test as outlined above.
If the gas supply line shut-off valve is open, close it,
and contact a qualified technician.
If You Need Assistance or Service:
Please reference the "Warranty" section of the Use and
Care Guide to contact service.