MENU → SETTINGS → Installer level → Installation configuration
The installed temperature sensor measures the current room temperature. The system con-
trol calculates a new target room temperature that is used to adjust the flow temperature.
– Difference = Set target room temperature - current room temperature
– New target room temperature = Set target room temperature + difference
Prerequisite: In the Zone assignment: function, the system control and/or the remote control
is assigned to the zone in which the system control or remote control is installed.
The Room temp. mod.: function is ineffective if No assignmt is activated in the Zone as-
signment: function.
→ Control type:
→ Zone
→ Zone activated:
→ Zone assignment:
→ Zone valve status:
→ Domestic hot water
→ Cylinder:
→ Target flow temperature: °C
→ Circulation pump:
→ Anti-legio. day:
→ Anti-legio. time:
→ Cylinder charging
hysteresis: K
0020288192_00 sensoHOME Operating and installation instructions
→ Active
Adjusting the flow temperature based on the cur-
rent room temperature.
→ Expan-
Adjusting the flow temperature based on the cur-
ded
rent room temperature. The system control also ac-
tivates/deactivates the zone.
– The zone is deactivated: Current room temper-
ature + 2/16 K > set room temperature
– Zone is activated: Current room temperature <
set room temperature - 3/16 K
2-point
Corresponds to an on/off control system
Analog.
Corresponds to a modulating control system
Deactivate zones that are not required. All existing zones appear
in the display.
Assign the system control and/or remote control to the selected
zone. The system control and/or remote control must be installed
in the selected zone. The control system also uses the room
temperature sensor for the assigned unit. The remote control
uses all of the values for the assigned zone. If no zone has been
assigned to the system control and/or the remote control, the
Room temp. mod.: function is ineffective.
If there is an existing domestic hot water cylinder, the Active
setting must be selected.
Define the days on which you want the anti-legionella function to
run. On these days, the water temperature is increased to above
60 °C. The circulation pump is activated. The function ends after
120 minutes at the latest.
If the Absence function is activated, the anti-legionella function is
not carried out. As soon as the Absence function ends, the anti-
legionella function is carried out.
Define the time at which you want the anti-legionella function to
run.
The cylinder charging starts as soon as cylinder temperature <
desired temperature - hysteresis value.
Product description 2