Steinberg Systems SBS-KW-1000/10O Manual De Instrucciones página 16

Balanzas de grúa
Ocultar thumbs Ver también para SBS-KW-1000/10O:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
LOAD 2 DETECTION
The scale displays LOAD2.
Load a standard weight, and press
. 00000 shows.
Press
or
and
, to modify the digit. Press
Press
, to input the decimal point.
Keep the load stable and press
, to display the weight code 34567.
Wait until the weight code is stable. Press
Once the detection finished, the scale automatically enters Load3 Detection.
LOAD 3 DETECTION
The scale displays LOAD3
Load a standard weight, and press
. 00000 shows.
Press
or
and
, to modify the digit. Press
Press
, to input the decimal point.
EN
Keep the load stable and press
, to display the weight code 45678.
Wait until the weight code is stable. Press
Once the detection finished, the scale automatically saves and exits the Calibration mode.
Problem
Possible Cause
discharged / defective battery
not power-on after
is pressed
defective
defective power cable
defective mainboard
display flashes
discharged battery
scale is disturbed
no action taken after key
pressed
defective key
REV. V 2016
or
, to move the digit. Input weight value.
, to start the weight detection.
or
, o move the digit. Input weight value.
, to start the weight detection.
Suggested Solution
check batteries and charge / exchange
the batteries
press harder and keep pressing 2sec
key
open front panel, check power cable
contact service representative
charge / exchange the batteries
Turn off and then turn the scale on
again
contact service representative
30
Problem
Possible Cause
load in motion
weak Anti-Motion
weight reading not stable
damped loadcell or mainboard
defective mainboard
weight reading not zero
discharged batteries
when no load
load-cell stressed too long
defective loadcell
large error in weight
scale not zeroed before applying
reading
load
wrong unit
scale requires calibration
defective loadcell or mainboard
short remote controlling
discharged / defective remote
distance
battery
REGULAR CONTROL OF THE DEVICE
Control regularly that the device doesn´t present any damage. If there is any damage, please stop using the
device. Please contact your customer service to solve the problem.
What to do in case of a problem?
Please contact your customer service and prepare following information:
Invoice number and serial number (the latter is to be found on the technical plate on the
device).
If relevant, a picture of the damaged, broken or defective part.
It will be easier for your customer service clerk to determine the source of the problem if you give
a detailed and precise description of the matter. The more detailed your information, the better the
customer service will be able to solve your problem rapidly and efficiently!
CAUTION: Never open the device without the authorization of your customer ser-
vice. This can lead to a loss of warranty!
REV. V 2016
Suggested Solution
keep load stable
change Anti-Motion level
dry loadcell or mainboard
contact service representative
charge / exchange the batteries
offload the weight
contact service representative
manual Zero scale before loading
switch to correct unit
calibrate scale
contact service representative
replace remote controller batteries
31
EN
Tabla de contenido
loading

Tabla de contenido