Hitachi Koki DS 9DM Instrucciones De Manejo página 11

Taladro atornillador a bateria
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
Table 1
Before
Blinks
charging
(RED)
While
Lights
charging
(RED)
Charging
Blinks
complete
(RED)
Charging
Flickers
impossible
(RED)
Overheat
Lights
standby
(GREEN)
NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling fan.
(2) Regarding the temperatures of the rechargeable
battery
The temperatures for rechargeable batteries are as
shown in the table below, and batteries that have
become hot should be cooled for a while before
being recharged.
Table 2 Temperatures at which the battery can be recharged
Charger
Rechargeable batteries
EB912S, EB914S, EB914,
EB9B, EB1212S, EB1214S,
EB1214L, EB1220BL
EB9H, EB926H, EB930H,
EB1222HL, EB1226HL,
EB1230HL, EB1233X
(3) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown
in Table 3.
Table 3 Charging time (At 20°C)
Charger
Battery
EB912S, EB914S,
EB914, EB1212S,
Approx. 30 min. Approx. 20 min.
EB1214S, EB1214L
EB9B, EB1220BL
Approx. 50 min. Approx. 30 min.
EB9H, EB1222HL
Approx. 55 min. Approx. 32 min.
EB926H, EB1226HL Approx. 60 min. Approx. 40 min.
EB930H, EB1230HL Approx. 70 min.. Approx. 45 min.
EB1233X
Approx. 75 min. Approx. 50 min.
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Lights continuously
UC14YFA
UC18YRL
–5°C – 60°C
–5°C – 55°C
0°C – 45°C
–5°C – 50°C
UC14YFA
UC18YRL
NOTE
The charging time may vary according to
temperature and power source voltage.
4. Disconnect the charger's power cord from the
receptacle
5. Hold the charger firmly and pull out the battery
NOTE
After operation, pull out batteries from the charger
first, and then keep the batteries properly.
Regarding electric discharge in case of new batteries,
etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might
be low when using them the first and second time.
This is a temporary phenomenon, and normal time
required for recharging will be restored by recharging
the batteries 2 – 3 times.
How to make the batteries perform longer.
(1) Recharge the batteries before they become
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the
electric current, the battery may be damaged and
its life will become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the
battery and recharge it after it has cooled for a
while.
English
Malfunction in the bat-
tery or the charger.
Battery overheated. Un-
able to charge (charge
will commence when
battery cools).
10
Tabla de contenido
loading

Este manual también es adecuado para:

Ds 12dm

Tabla de contenido