Caution! Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
30 mm
A
min 20 mm
60 mm
(max 150 mm)
B
a) Removable panel
Technical information
Hob dimensions
Width:
Length:
Hob recess dimensions
Width:
Length:
20
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the indi-
cation and the kitchen unit must be equipped
with vents to let a continuous supply of air. The
electrical connection of the hob and the oven
must be installed separately for safety reasons
and to let easy remove oven from the unit.
Hot plate rating
290 mm
510 mm
270 mm
490 mm
50 cm
360 cm
Rear cooking zone 180
mm
Front cooking zone 145
mm
Total rating
Electric supply
2
120 cm
2
180 cm
1.7 kW
1.2 kW
2.9 kW
230 V ~ 50 Hz
www.zanussi.com
2