Reset Function - Grundfos Oxiperm OCD-164 Serie Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para Oxiperm OCD-164 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 157
Level 1: Operators
Authorisation for the menus "Automatic, "Manual operation",
"Logbook" and "local/remote".
Level 2: Parameters
unlimited privileges
Level 1 and 2 are set to "0" each. This means
Note
unlimited privileges without password scanning.
The entered codes are reset by entering the number
Note
"1998". Then both levels are reset to "0".
In the "Basic setting" menu, scroll to page 2 using the
[ARROW RIGHT] key.
Switch to "Code function" menu using the [F1] key.
Code function
1 Level 1
2 Level 2
Switch to operator selection using [F1] key.
Level 1 operator
Code: 0
Activate the input field using [F1] key.
Enter code (max. 4 digits) using the arrow keys [RIGHT],
[LEFT], (UP], and [DOWN].
Confirm using [Enter] key.
Use the [Enter] or [Escape] key to return to the "Code
function" menu.
Switch to "Level 2 Parameters" using [F2] key.
Activate the input field using [F1] key.
Enter code as described for "Level 1".
Use the [Enter] or [Escape] key to return to the "Code
function" menu.
Use [Escape] key again to return to "Basic setting" menu.

6.8.5 Reset function

In the "Basic setting" menu, select the reset function using the
[F2] key, or scroll in the "Basic setting" menu.
Reset function
Code: xxxx
Input password
Switch to the input field using the [F1] key, enter new code
using the arrow keys [RIGHT], [LEFT], [UP], and [DOWN],
enter code.Reset code: 6742
Confirm using [Enter] key.
Use the [Enter] or [Escape] key to return to the "Basic setting"
menu.
6.8.6 Date/time
In the "Basic setting" menu, select the "Date/time" menu using
the [F3] key.
Time setting
1 Time
2 Date
3 Daylight sav.
Time
Switch to the "Time" menu using the [F1] key.
Time setting
New
XX:YY:ZZ
2 Accept
Use the [F1] key to activate the input fields for hours (XX),
minutes (YY) and seconds (ZZ) (input field flashing). Switch from
hours to minutes or seconds by pressing the [F1] key again.
Use the [Escape] key to deactivate the input field.
Setting the time
Following activation of the respective input field using the [F1]
key, set the new value using the arrow keys [RIGHT], [LEFT],
[UP], and [DOWN].
Confirm the new value in each case using the [Enter] key
(input field no longer flashes).
Once all values have been set and confirmed using the [Enter]
key, press the [F2] key (accept) to update the new time.
Return to the "time setting" menu with the [escape] key, by
pressing the [escape] key once again return to the "setup"
menu.
Setting the date/day of week
Switch to the "Date setting" menu using the [F2] key.
Date setting
New
XX.YY.ZZ
2 Accept
Switch to the "Day of week" menu using the arrow [RIGHT]
key, and back to the "Date setting" menu using the arrow
[LEFT] key.
Day of week
New
XX.YY.ZZ
XX
2 Accept
The setting is made analogous to the time setting, i.e. activate
input fields using the [F1] key, set new value using the arrow keys
[RIGHT], [LEFT], (UP], and [DOWN], and confirm with [Enter].
The new value is updated by pressing the [F2] key (accept).
Use the [Escape] key to return to the "Time setting" menu.
Daylight saving time
Switch to the "Daylight saving time" menu using the [F3] key.
Daylight saving time
Switch
Activate the input field using the [F1] key (input field flashing).
Various settings can be selected using the [UP] and [DOWN]
arrow keys.
Settings
ON
Direct switching to daylight saving time
MANUAL
Manual entering of daylight saving time
EU
Pre-setting of daylight saving time for EU countries
Confirm the settings using the [Enter] key.
Use the [Escape] key to return to the "Time setting" menu.
Current
17.07.02
Current
15.05.02
Current
15.05.02
Monday
off
<off>
>
23
Tabla de contenido
loading

Tabla de contenido