When using an electrical appliance, basic precautions should always be followed, including
the following: READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.
WARNING
– TO REDUCE THE RISk OF FIRE, ELECTRIC
SHOCk OR INJURY:
1. Do not leave appliance when plugged in. Unplug from outlet when not in use and before servic-
ing. Connect to a properly grounded outlet only. See Grounding Instructions.
2. Do not expose to rain – store indoors.
3. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
4. Use only as described in this manual. Use only Manufacturer's recommended attachments.
5. Do not use with damaged cord or plug. If appliance is not working as it should, has been
dropped, damaged, left outdoors or dropped into water, contact Shop-Vac Corporation for
assistance.
6. Do Not: pull or carry by cord, use cord as a handle, close a door on cord or pull cord around
sharp edges or corners. Do not run appliance over cord. keep cord away from heated surfaces.
7. Do not unplug by pulling on cord. To unplug, grasp the plug; not the cord.
8. Do not handle plug or appliance with wet hands.
9. Do not put any object into openings. Do not use with any openings blocked; keep free of dust,
lint, hair and anything that may reduce air flow.
10. keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.
11. Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
WARNING
– DO NOT LEAVE VACUUM UNATTENDED WHEN IT IS PLUGGED IN AND/OR OPERATING. UNPLUG UNIT WHEN NOT IN USE.
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a
path of least resistance for electric current to reduce the risk of electric shock. This appliance is
equipped with a cord having an equipment-grounding conductor and grounding plug. The plug
must be inserted into an appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING
– IMPROPER CONNECTION OF THE EqUIPMENT-
GROUNDING CONDUCTOR CAN RESULT IN A RISk OF ELECTRIC
SHOCk. CHECk WITH A qUALIFIED ELECTRICIAN OR SERVICE
PERSON IF YOU ARE IN DOUBT AS TO WHETHER THE OUTLET IS
PROPERLY GROUNDED. DO NOT MODIFY THE PLUG PROVIDED WITH
THE APPLIANCE – IF IT WILL NOT FIT THE OUTLET, HAVE A PROPER
OUTLET INSTALLED BY A qUALIFIED ELECTRICIAN.
This appliance is for use on a nominal 120-volt circuit, and has a grounded plug that
like the plug illustrated in sketch A. A temporary adapter that looks like the adapter illustrated in
When using the appliance at a distance where an extension cord becomes necessary, a 3-con-
ductor grounding cord
Volts
of adequate size must
120V
be used for safety,
Ampere Rating
and to prevent loss of
More
Not More
power and overheat-
Than
ing. Use the table
0-6
below to determine
6-10
A.W.G. wire size re-
10-12
quired. To determine
12-16
UNPACkING AND SET-UP
1. Pull lid latches in an outward motion, remove tank cover and any accessories that may have
been shipped in tank.
2. Attach caster feet, casters and rear dolly following the instructions and illustrations in this
manual.
3. Attach carriage handle following instructions and illustrations in this manual.
4. Before replacing tank cover, refer to Dry Pick-up or Wet Pick-up Operation in this manual to
ensure you have the proper filters installed for your cleaning operation.
5. Replace tank cover and apply pressure with thumb to each latch until it snaps tightly in place.
Make sure all lid latches are clamped securely.
6. Insert long machine hose end with locking-nut into inlet of tank and tighten. Do not over-
tighten.
7. Attach the extension wands to the accessory end
of the hose. Twist slightly to tighten the connection
(Figure 1).
8. Attach one of the cleaning accessories (depending
on your cleaning requirements) on the extension
wands. Twist slightly to tighten the connection (Figure 1).
9. Plug the cord into the wall outlet. your cleaner is ready for use.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
EXTENSION CORDS
Total length of cord in feet
25
50
100
AWG
Than
18
16
16
18
16
14
16
16
14
14
12
Not recommended
1
12. Do not use without dust bag and/or filters in place.
13. Turn off all controls before unplugging.
14. Use extra care when cleaning on stairs.
15. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where
they may be present.
16. Do not use your cleaner as a sprayer of flammable liquids such as oil base paints, lacquers,
household cleaners, etc.
17. Do not vacuum toxic, carcinogenic, combustible or other hazardous materials such as asbestos,
arsenic, barium, beryllium, lead, pesticides or other health endangering materials. Specially
designed units are available for these purposes.
18. Do not pick up wood or coal ash; soot, cement, plaster or drywall dust without cartridge filter
in place. These are very fine particles that may pass through a foam and disc filter and affect
the performance of the motor or be exhausted back into the air.
19. Do not leave the cord lying on the floor once you have finished the cleaning job. It can become
a tripping hazard.
20. Use special care when emptying heavily loaded tanks.
21. To avoid spontaneous combustion, empty tank after each use.
22. The operation of a utility vac can result in foreign objects being blown into eyes, which can result
in eye damage. Always wear safety goggles when operating vacuum.
23. STAy ALERT. Watch what you are doing and use common sense. Do not use vacuum cleaner
when you are tired, distracted or under the influence of drugs, alcohol or medication causing
diminished control.
sketches B and C may be used to connect this plug to a 2-pole receptacle as shown in sketch B
if a properly grounded outlet is not
available. The temporary adapter
should be used only until a properly
grounded outlet (sketch A) can be
installed by a qualified electrician.
The green colored rigid ear, lug or
the like extending from the adapter
must be connected to a permanent
ground such as a properly grounded
outlet box cover. Whenever the
adapter is used, it must be held in
place by a metal screw.
IN CANADA, THE USE Of A TEMPORARy ADAPTOR IS NOT PERMITTED By THE CANADIAN
ELECTRICAL CODE. Make sure that the appliance is connected to an outlet having the same
looks
configuration as the plug. No adapter should be used with this appliance.
ampere rating of your vacuum, refer to nameplate located on rear of motor cover.
Before using appliance, inspect power cord for loose or exposed wires and damaged insulation.
Make any needed repairs or replacements before using your appliance. Use only three-wire
150
outdoor extension cords which have three-prong grounding-type plugs and three-pole receptacles
which accept the extension cord's plug. When vacuuming liquids, be sure the extension cord con-
nection does not come in contact with the liquid.
14
NOTE: STATIC SHOCkS ARE COMMON IN DRy AREAS OR WHEN THE RELATIVE HUMIDITy Of THE
12
AIR IS LOW. THIS IS ONLy TEMPORARy AND DOES NOT AffECT THE USE Of THE APPLIANCE. TO
12
REDUCE THE fREqUENCy Of STATIC SHOCkS IN yOUR HOME, THE BEST REMEDy IS TO ADD
MOISTURE TO THE AIR WITH A CONSOLE OR INSTALLED HUMIDIfIER.
I=ON, O=OFF
NOTE: MANy MORE USEfUL TOOLS ARE AVAILABLE AT yOUR LOCAL DEALER OR SHOP-
VAC® WEBSITE.
REAR WHEEL DOLLY/TOOL HOLDER
AND FRONT CASTER FEET ASSEMBLY
you will find two casters (a.), two large rear wheels (b.), one axle (c.), rear dolly/
basket (d.), two caster feet (e.) and four screws with your wet/dry vacuum. Assemble as follows:
a
b
1. With cord disconnected from receptacle and tank cover removed, turn tank upside down so that the
bottom is facing up.
2. Place axle upright on a hard surface and hammer on (1) cap nut. Place (1) wheel on axle and slide
c
d
e