Installing And Connecting The Pump - Dometic PowerPump PP127 Instrucciones De Montaje

Bomba de agua a presión
Ocultar thumbs Ver también para PowerPump PP127:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29

Installing and connecting the pump

6
Installing and connecting the pump
6.1
Installing the pump
NOTICE!
A
Choose an installation location where the pump will be protected
from water penetration and moisture.
NOTE
I
When selecting the installation location, note the following:
 The pump can be installed either horizontally or vertically (with
the pump motor at the top).
 A coarse filter must be used in the pump inlet. If you install the
pump in a place which is not readily accessible, instead of using
the coarse filter provided (which is inserted directly onto the
pump) you can use a different coarse filter in a more accessible
place.
➤ Remove the plugs (fig. 1 7, page 2) from the connections.
➤ If necessary, open the slide valves (fig. 2 1, page 2) on the inlet and
outlet.
➤ Insert the coarse filter (fig. 2 3, page 2) in the inlet and a suitable adapter
(fig. 2 2, page 2) in the outlet.
➤ Lock the adapter and coarse filter with the slide valve (fig. 2 1, page 2).
➤ Slide the four fastening feet (fig. 1 6, page 2) into the holders.
➤ Install the pump in a vibration-free location using suitable fastening mate-
rials.
6.2
Connecting the pump to the water system
➤ Connect the pump to the water system using suitable pressure-proof con-
nection hoses (
➤ Fix the hoses to the connections using hose clamps.
➤ In the water system, attach pipes of at least
16
1
/
").
2
PowerPump
3
/
" to the fittings.
8
EN
Tabla de contenido
loading

Tabla de contenido