5. Fitting a pressure gauge
To connect a pressure gauge to the air-driven pump or
oil injector:
•
Remove the gauge plug.
•
Screw the pressure gauge firmly into the G
connection assembly.
Attention: Connector B, shown in the next two
illustrations, has left-hand threads!
•
Adjust the connection assembly until a gap of
approximately 1 mm remains between connectors
A and B.
•
Screw the complete assembly, including A, B and
the pressure gauge, into the pump or injector
body.
•
Maintain the 1 mm gap during installation.
•
When connector A is almost tight, turn the
pressure gauge to the correct position.
•
Tighten connector A completely.
•
Do not tighten on connector B.
12
/
1
2
SKF THAP 030E 150E 300E 400E