Troubleshooting Guide - Metabo HPT DH 36DPA Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

● To avoid injury from an accidental start, turn the switch OFF and remove the plug from the power source
or remove the battery from the main body before making any adjustments.
● All electrical or mechanical repairs should be done only by qualifi ed service technicians. Contact
metabo HPT Authorized Service Center.
1. Power tool
Symptom
Tool doesn't run
Tool suddenly stopped
Tool bits
-can't be attached
-fall off
Holes can't be smoothly
drilled.
Screw head slip and
comes loose
Battery cannot be
installed

TROUBLESHOOTING GUIDE

WARNING
Possible cause
No remaining battery power
Battery isn't securely attached.
Concrete dust has accumulated on
the terminals of the battery installation
compartment as well as on the battery
sliding grooves.
The battery was attached while the switch
trigger was ON.
Tool was overburdened
Reactive force control was activated
Battery or tool overheated
The shape of the attachment portion
doesn't match
The drill is worn
The drill is rotating in reverse.
Bit number doesn't match with the screw
size.
The bit is worn.
Attempting to install a battery other than
that specifi ed for the tool.
Remedy
Charge the battery.
Push in the battery until a click is heard.
Clean off the accumulated concrete dust
with a dry cloth.
Attach the battery when the switch trigger
is OFF.
Remove the cause of the overburdening.
See "Reactive force control".
Allow the tool and battery to thoroughly
cool.
For the SDS-plus shank type, use a bit with
a diameter that is within the designated
range.
Replace with a new drill.
Switch to forward rotation.
Install a suitable bit.
Replace with a new bit.
Please install a multi volt type battery.
English
21
Tabla de contenido
loading

Tabla de contenido